LogoLogo
Registration GuideTroubleshoot RegistrationProfiles Guide
  • RAPT Portal - Introduction
  • Getting Started
  • Dashboard
  • Equipment
    • Devices
    • RAPT BrewZilla
      • Get Started!
      • Setup & Assembly
      • Manual Operation with the Digital Controller
      • Remote Operation with the RAPT Portal
      • Brewing with RAPT Gen 4 BrewZilla
      • Using the RAPT Bluetooth Thermometer
      • Profiles
      • Menus
      • Troubleshoot BrewZilla
      • Convert Single Phase to Three Phase (100L Gen 4 BrewZilla only)
      • RAPT Device Boot Loop Troubleshooting & Recovery Mode
    • RAPT Can Filler
      • Getting Started
      • Setup
      • Operation
      • Cleaning
      • Antenna Upgrade
      • Installing KL38171 Instant Read Water Resistant Probe
      • Installing KB22681 Slimline Fill Tube Kit
      • Troubleshooting Can Filler
      • RAPT Device Boot Loop Troubleshooting & Recovery Mode
    • RAPT Fermentation Chamber
      • Get Started!
      • Setup
      • Operation
      • Profiles
      • Menus
      • Bluetooth
      • Screen Change For RAPT Fermentation Chamber
      • Troubleshooting
      • RAPT Device Boot Loop Troubleshooting & Recovery Mode
    • RAPT Pill Hydrometer
      • Get Started!
      • RAPT Pill Captive Portal
      • Calibration
        • Standard Calibration
        • Advanced Calibration
        • Custom Calibration
      • Operation
      • Bluetooth Operation
      • Pill Wireless Charger Upgrade - Installation
      • Troubleshooting
    • RAPT Temperature Controller
      • Get Started!
      • Setup
      • Operation
      • Profiles
      • Menus
      • Bluetooth
      • Troubleshooting
      • RAPT Device Boot Loop Troubleshooting & Recovery Mode
    • RAPT Bluetooth Thermometer
      • Assembly & Setup
      • Bluetooth Operation
      • Settings
  • Profiles
    • Starting or Stopping a Profile
    • Creating and Editing Profiles
      • BrewZilla Profiles
        • Advanced BrewZilla Profiles
      • General Temperature Control Profiles
      • Pill Hydrometer Profiles
      • Fermentation Profiles
    • My Profiles
    • Search Profiles
    • Device Profile Sessions
      • Profile Session Time Travel (Skip Steps)
  • Tools
    • ABV Calculator
    • Colour Converter
    • Wort Dilution Calculator
    • Hydrometer Temperature Adjustment Calculator
  • My Account
  • Troubleshooting
Powered by GitBook
On this page
  • Create Pill Hydrometer Profile Session with Alerts
  • Start Profile Session without Alerts (Logging Only)
  • Alerts
  • Sample Profile (with Alerts)
  1. Profiles
  2. Creating and Editing Profiles

Pill Hydrometer Profiles

RAPT Portal | Pill Hydrometer Profiles

PreviousGeneral Temperature Control ProfilesNextFermentation Profiles

Last updated 1 month ago

Create Pill Hydrometer Profile Session with Alerts

To create a Pill Hydrometer Profile, Click the Add Profile button in the top left.

Then, select a Profile Type: Fermentation

Next, select a Name for your Profile (such as Belgian Dubbel)

Enter a Description for your Profile - this can be anything and is just intended for your reference.

Pill Hydrometer Profiles are different to other RAPT Profiles as RAPT Pill Hydrometers are purely measurement instruments.

Pill Hydrometer Profiles are a way to set up Alerts based on the telemetry received from the Pill.

This is extremely useful, especially if you are not using the Pill Hydrometer in conjunction with another RAPT device.

RAPT Pill Hydrometers will measure temperature, gravity and gravity velocity (rate of change of gravity over a specified interval).

You can set up alerts based on any of these.

For example, you can set an alert for when the gravity drops to (for example) 1.025 at which point you may wish to raise the fermentation temperature for a diacetyl rest.

You can set an alert for the gravity velocity to drop to 0, at which point fermentation is likely finished and you can begin a cold crash.

This will bring up a new dialog box which allows you to select and enter the desired alert details.

Start Profile Session without Alerts (Logging Only)

If you just wish to record telemetry over a set interval and do not need any alerts (if not doing a dry hop, for example) then a Pill Hydrometer Profile Session can be started directly from the Dashboard of the RAPT Portal.

In the RAPT Portal, select the Pill you wish to begin a Profile Session on.

This will open a dropdown menu

Device: You can select the RAPT Pill Hydrometer or RAPT Bluetooth Thermometer from this menu

Profile: This is a Logging Only Profile Session with no alerts. To create a Profile with Alerts, select the Create Profile option

Name: You can enter a name for the Profile Session. This is useful as all sessions are saved in the Profile History so a name makes it much easier to identify each Session

Start Date: You may select a Date and Time to begin the Profile Session. This is extremely useful as often telemetry is not received immediately after placing the Pill in the fermenter (for examlpe). You may choose a time an hour or two after pitching yeast and putting the Pill in the fermenter to ensure that the first received telemetry in the Profile Session is up to date and accurate

Alerts

Alerts allows you to set up a custom alert for each step. You can add as many Alerts for each step as desired. You can select when to send the alert and also enter a custom Alert message (such as "Add Boil Hops Now")

You can set an alert when:

  • The gravity velocity is greater/less than the specified value reaches {a specified temperature} - select the operator Less Than or Greater Than and Input a Gravity Velocity (in points per day, where one Point = 0.001 sg) and Alert Message

  • The gravity reaches {a specified gravity} - select the operator Less Than or Greater Than and Input a Specific Gravity and Alert Message

  • The temperature reaches {a specified temperature} - select the operator Less Than or Greater Than and Input a Temperature and Alert Message

In order to receive alerts you need to select Enable Mobile App (Push) Notifications in the My Account settings. You must also enable notifications for the Google Play or App Store App on your mobile device.

Congratulations! You have made a Pill Hydrometer profile and are ready to brew!

Sample Profile (with Alerts)

There are many reasons to have Alerts generated during fermentation. As the Pill can measure Temperature, Gravity and also Gravity Velocity it is super easy to set up triggers for Alerts at various important stages of fermentation.

For example, during a fairly standard fermentation you may wish to be notified when the Gravity Velocity has dropped to the point that it is desirable to start increasing fermentation temperature.

An alert to add dry hops can be added at any point.

An alert to check fermentation is done (or notify when it is finished using Gravity Velocity) is very useful.

Using Pill Hydrometer Profile Sessions you can essentially set a custom alert to be notified at any point during fermentation, greatly improving the ease of fermentation

To download and import a Sample Pill Hydrometer Profile Session, please use this link.

Once added to your RAPT Profile Library, you can edit or change this as desired

Click the Add button to add a Alert

Press the Play Button to begin a profile session. NOTE: If the Play button is not visible a Profile Session may already be running. Select the Stop button first.

To receive alerts on your mobile device, you must have the or app installed.

Once you are happy that all the Alerts are correct, make sure you hit the Save button to save the profile to your My Profiles library. You can then send it directly to your RAPT device using the Send Profile to Device button or using the Play button in the Dashboard to start a new profile!

Google Play
Apple App Store
Sample Pill Hydrometer Session Profile
Pill Profile Session Dropdown
Gravity Velocity Alert Option
Gravity Alert Option
Temperature Alert Option