LogoLogo
Registration GuideTroubleshoot RegistrationProfiles Guide
  • RAPT Portal - Introduction
  • Getting Started
  • Dashboard
  • Equipment
    • Devices
    • RAPT BrewZilla
      • Get Started!
      • Setup & Assembly
      • Manual Operation with the Digital Controller
      • Remote Operation with the RAPT Portal
      • Brewing with RAPT Gen 4 BrewZilla
      • Using the RAPT Bluetooth Thermometer
      • Profiles
      • Menus
      • Troubleshoot BrewZilla
      • Convert Single Phase to Three Phase (100L Gen 4 BrewZilla only)
      • RAPT Device Boot Loop Troubleshooting & Recovery Mode
    • RAPT Can Filler
      • Getting Started
      • Setup
      • Operation
      • Cleaning
      • Antenna Upgrade
      • Installing KL38171 Instant Read Water Resistant Probe
      • Installing KB22681 Slimline Fill Tube Kit
      • Troubleshooting Can Filler
      • RAPT Device Boot Loop Troubleshooting & Recovery Mode
    • RAPT Fermentation Chamber
      • Get Started!
      • Setup
      • Operation
      • Profiles
      • Menus
      • Bluetooth
      • Screen Change For RAPT Fermentation Chamber
      • Troubleshooting
      • RAPT Device Boot Loop Troubleshooting & Recovery Mode
    • RAPT Pill Hydrometer
      • Get Started!
      • RAPT Pill Captive Portal
      • Calibration
        • Standard Calibration
        • Advanced Calibration
        • Custom Calibration
      • Operation
      • Bluetooth Operation
      • Pill Wireless Charger Upgrade - Installation
      • Troubleshooting
    • RAPT Temperature Controller
      • Get Started!
      • Setup
      • Operation
      • Profiles
      • Menus
      • Bluetooth
      • Troubleshooting
      • RAPT Device Boot Loop Troubleshooting & Recovery Mode
    • RAPT Bluetooth Thermometer
      • Assembly & Setup
      • Bluetooth Operation
      • Settings
  • Profiles
    • Starting or Stopping a Profile
    • Creating and Editing Profiles
      • BrewZilla Profiles
        • Advanced BrewZilla Profiles
      • General Temperature Control Profiles
      • Pill Hydrometer Profiles
      • Fermentation Profiles
    • My Profiles
    • Search Profiles
    • Device Profile Sessions
      • Profile Session Time Travel (Skip Steps)
  • Tools
    • ABV Calculator
    • Colour Converter
    • Wort Dilution Calculator
    • Hydrometer Temperature Adjustment Calculator
  • My Account
  • Troubleshooting
Powered by GitBook
On this page
  • Overview
  • WiFi
  • Registration
  • Settings
  • Diagnostics
  • Calibration
  1. Equipment
  2. RAPT Pill Hydrometer

RAPT Pill Captive Portal

RAPT Pill Hydrometer & Thermometer - Captive Portal Guide

PreviousGet Started!NextCalibration

Last updated 7 months ago

Overview

The Rapt Pill Captive Portal can only be accessed when the RAPT Pill is plugged in to USB-C or (Wireless Charging ONLY) charging on the Wireless Charging base. Note. The battery needs to have sufficient charge to broadcast the Captive Portal when wireless charging is usedYou can access the Captive Portal in two ways. You can connect directly to the Pill’s WiFi using a phone, tablet or computer. Simply connect to the Pill’s WiFi network (the network name will be in the form RAPT Pill XXXX where the last 4 digits correspond to the last digits of the Pill’s MAC address).

Alternatively, once the Pill has been connected to your WiFi network, you can access the Captive Portal by entering the Pill’s IP address on a browser. The IP address can be found in the Diagnostics screen of the Captive Portal.

Note: The Pill Captive Portal will close automatically after 10 minutes when the Pill is plugged in to USB-C. If the Pill is disconnected from USB-C within 10 minutes the Pill Captive Portal will close.

This is by design to maximise battery life.

To keep the Captive Portal open for up to 10 minutes while disconnected from USB-C (for example, in order to perform calibration of the Pill) you must first open the Diagnostics or the Calibration screen of the Pill Captive Portal.

There are five options available in the Captive Portal.

WiFi

  • CONNECTED TO: This displays the WiFI Network the RAPT Pill is currently connected to

  • MANUAL CONNECT: This allows you to input a (hidden) SSID (if your network is hidden or private, for example)

  • OR CHOOSE A NETWORK: You can select any visible WiFi network top connect the RAPT Pill to

Registration

The Registraion screen will display the Pill's MAC Address and Validation Code (if the Pill is connected to WIFI but not registered) or REGISTRATION DONE (as above) if the Pill is sucessfully registered to the RAPT Portal.

Settings

  • Telemetry method - select either WiFI or Bluetooth

  • Telemetry interval - set the desired inteval for telemetry

  • Gravity velocity measurement time - select the period over which gravity velocity (rate of change of gravity) is measured. We recommend 1 day for meaningful results

  • Temperature offset - set the offset (up to +/- 10°C) if the on board thermeometer needs calibrating*

*The RAPT Pill temperature reading will usually be high during Captive Portal access, charging or calibration. This is because the Li-ion battery can generate quite a bit of heat in sustained use.

Diagnostics

SENSOR VALUES

  • Accelerometer X/Y/Z: current accelerometer reading

  • Tilt Angle: current tilt angle

  • Specific Gravity: current gravity reading

  • ADC2: current ADC2 (analogue to digital) reading

  • Battery: current battery charge level*

  • Temperature: current temperature**

  • Firmware: current firmware version

  • MAC address: Pill MAC address (required for Registration)

  • IP (STA): IP address (static)***

  • IP (AP): IP address (access point)

  • Telemetry sent XX/YY: telemetry sent(XX) / telemetry recevied (YY)

*not displayed until battery is calibrated ** typically not accurate when Pill Captive Portal is open, as the battery generates heat when charging *** Will display 0.0.0.0 if the Pill is not connected to WiFI

GRAVITY VELOCITY

  • Valid: true or false

  • Gravity velocity: current gravity velocity

  • Age of latest: last gravity velocity reading telemetry reading

  • Dataset size: number of data points

  • Oldest item: oldest reading

ACTIONS

  • Send telemetry now - manually send telemtry to the RAPT Portal

  • Check for new firmware - check for firmware updates

  • Send diagnostics log - send diagnostic data (only at the request of help desk)

  • Reboot device - reboots RAPT Pill (useful if you ahave WIFI connectivity issues)

  • Factory reset - restores Pill to default factory settings. Warning - clears WiFI and Registration settings

  • Get gravity data - downloads .csv of gravity data

Calibration

In this screen you can perform , or calibration. You can also Clear an existing calibration.

Standard
Advanced
Custom