LogoLogo
Registration GuideTroubleshoot RegistrationProfiles Guide
  • RAPT Portal - Introduction
  • Getting Started
  • Dashboard
  • Equipment
    • Devices
    • RAPT BrewZilla
      • Get Started!
      • Setup & Assembly
      • Manual Operation with the Digital Controller
      • Remote Operation with the RAPT Portal
      • Brewing with RAPT Gen 4 BrewZilla
      • Using the RAPT Bluetooth Thermometer
      • Profiles
      • Menus
      • Troubleshoot BrewZilla
      • Convert Single Phase to Three Phase (100L Gen 4 BrewZilla only)
      • RAPT Device Boot Loop Troubleshooting & Recovery Mode
    • RAPT Can Filler
      • Getting Started
      • Setup
      • Operation
      • Cleaning
      • Antenna Upgrade
      • Installing KL38171 Instant Read Water Resistant Probe
      • Installing KB22681 Slimline Fill Tube Kit
      • Troubleshooting Can Filler
      • RAPT Device Boot Loop Troubleshooting & Recovery Mode
    • RAPT Fermentation Chamber
      • Get Started!
      • Setup
      • Operation
      • Profiles
      • Menus
      • Bluetooth
      • Screen Change For RAPT Fermentation Chamber
      • Troubleshooting
      • RAPT Device Boot Loop Troubleshooting & Recovery Mode
    • RAPT Pill Hydrometer
      • Get Started!
      • RAPT Pill Captive Portal
      • Calibration
        • Standard Calibration
        • Advanced Calibration
        • Custom Calibration
      • Operation
      • Bluetooth Operation
      • Pill Wireless Charger Upgrade - Installation
      • Troubleshooting
    • RAPT Temperature Controller
      • Get Started!
      • Setup
      • Operation
      • Profiles
      • Menus
      • Bluetooth
      • Troubleshooting
      • RAPT Device Boot Loop Troubleshooting & Recovery Mode
    • RAPT Bluetooth Thermometer
      • Assembly & Setup
      • Bluetooth Operation
      • Settings
  • Profiles
    • Starting or Stopping a Profile
    • Creating and Editing Profiles
      • BrewZilla Profiles
        • Advanced BrewZilla Profiles
      • General Temperature Control Profiles
      • Pill Hydrometer Profiles
      • Fermentation Profiles
    • My Profiles
    • Search Profiles
    • Device Profile Sessions
      • Profile Session Time Travel (Skip Steps)
  • Tools
    • ABV Calculator
    • Colour Converter
    • Wort Dilution Calculator
    • Hydrometer Temperature Adjustment Calculator
  • My Account
  • Troubleshooting
Powered by GitBook
On this page
  • Register Device
  • Profiles
  • Settings
  • Bluetooth
  • Diagnostics
  • About
  1. Equipment
  2. RAPT Fermentation Chamber

Menus

Menu Guide | RAPT Fermentation Chamber

PreviousProfilesNextBluetooth

Last updated 12 days ago

The RAPT Fermentation Chamber is designed to be largely controlled through the RAPT Portal.

There are various on board functions which can be accessed directly through the on board menu.

To use the on board menu, use the Up or Down buttons to navigate. Use the Select button to select or enter a function once highlighted. Use the Return button to escape from a Menu option or return to the prvious screen. Selecting Back will not save any changes.

Register Device

This option will only be available when the RAPT Fermentation Chamber is not registered to the RAPT Portal. For a step by step guide to registering your RAPT Fermentation Chamber please refer to

Profiles

To access currently running Profiles, or Profiles that have been uploaded to the device, navigate to and select Profiles in the menu. From this menu, available Profiles can be started, stopped and paused.

Active profiles can also be skipped to another step or reverted to a previous step. Please refer to for a full guide.

Settings

The following options are available in the Settings Menu.

To change any of the advanced settings enter the Menu by pressing Select . Once in the menu navigate to Settings and press Select

Up or Down buttons to adjust the set value for the setting. To save your setting hit Select . To return to the menu without saving choose Return

Some options are on/off toggles that can be activated or deactivated from the Settings Menu directly.

SETTING
PARAMETER

Temperature Sensor

Select built-in probe or select any Bonded Bluetooth RAPT Pill & Hydrometer

Show Graph

Toggles display between the graph or a numerical display

Unit System

Toggles between metric or imperial data

Graph zoom level

Select the date range displayed on the graph (default 7 days)

Cooling Hysteresis

Sets the cooling hysteresis (range 0.0°C-10°C, default 1°C)

Heating Hysteresis

Sets the heating hysteresis (range 0.0°C-10°C, default 1°C)

Compressor Cooldown

Sets the minimum compressor delay (Range 0-10 minutes, default 5 minutes)

Mode Switch Delay

Sets the minimum mode switch delay (Range 0-30 minutes, default 15 minutes)

Cooler Enabled

Toggles cooling on or off (when unchecked, the cooling will not operate irrespective of other settings)

Heater Enabled

Toggles heating on or off (when unchecked, the heater will not operate irrespective of other settings)

Bluetooth Enabled

Allowed Sensor Diff.

Sensor timeout

Sounds Enabled

Toggles device sounds on or off

Calibration Point 1

Calibration Point 2

Forget Calibration

Deletes saved calibration settings and restores defaults

NTC Beta

Enter the NTC Beta of an external temperature probe. The default is 3950

NTC Ref. Temperature

Enter the NTC Ref. Temperature of an external temperature probe. The default is 298.2

NTC Ref. Resistance

Enter the NTC Ref. Resistance of an external temperature probe. The default is 100000

Relay Cycle Time

Sets the allowed cycle time for PID heating (Range 5-3600 seconds, default 5 seconds)

PID Heating

Toggles PID heating on or off (recommended for advanced users only)

Heat P Coefficient

Enter desired proportional PID coefficient (Default 0.500)

Heat I Coefficient

Enter desired integral PID coefficient (Default 0.0000)

Heat D Coefficient

Enter desired derivative PID coefficient (Default 0.0000)

Forget WiFi Config

Forgets existing WiFi config - useful if you change WiFI networks

Disable WiFi

Disables WiFi (if you wish to not use the RAPT Portal and have only manual control)

Clear Registration

Low Temp. Alarm

This is the temperature below which an alarm will sound (default -10°C)

High Temp. Alarm

This is the temperature above which an alarm will sound (default 50°C)

Check For OTA Update

Manually check and download any available firmware updates

Bluetooth

Diagnostics

The Diagnostics menu contains information about the RAPT Fermentation Chamber. This includes such information as current firmware version, Wi-Fi network and signal strength, MAC address and IP address of the device.

About

The About menu contains information specific to the firmware and software of the RAPT Fermentation Chamber and associated devices, including but not limited to copyright information, acknowledgment of open source properties used, legal information etc.

Toggles on or off

This sets the allowed temperature differential between the built in probe and the current setpoint when using a Bluetooth device for temperature control (range 1°C-50°C, default 5°C). See

Sets the timeout if a device drops out (reverts to internal probe) (Range 5-1800 seconds, default 900 seconds)

First Calibration Point (see )

Second Calibration Point (see )

Clears RAPT Portal registration (see )

Bluetooth needs to first be enabled in the menu (above).

To Bond a Bluetooth enabled RAPT devices, use the Up or Down buttons to scroll to select the device. Choose Select button to Bond the device, or the Return button to cancel.

Once Bonded, the device will be visible in the Bonded section of the Bluetooth Menu. To Unbond, select the device with the navigation arrows and choose Select buttont to Unbond the device, or the Return button to cancel.

For more information about Bluetooth operation refer to the section.

Bluetooth
Settings
Calibration
Calibration
Troubleshooting
Bluetooth functionality
Bluetooth Operation