Menus
Menu Guide | RAPT Temperature Controller
Last updated
Menu Guide | RAPT Temperature Controller
Last updated
The RAPT Temperature Controller is designed to be largely controlled through the RAPT Portal.
There are various on board functions which can be accessed directly through the on board menu.
To use the on board menu, use the Up or Down buttons to navigate. Use the Select button to select or enter a function once highlighted. Use the Return button to escape from a Menu option or return to the prvious screen. Selecting Back will not save any changes.
This option will only be available when the RAPT Temperature Controller is not registered to the RAPT Portal. For a step by step guide to registering your RAPT Temperature Controller please refer to Getting Started
To access currently running Profiles, or Profiles that have been uploaded to the device, navigate to and select Profiles in the menu. From this menu, available Profiles can be started, stopped and paused.
Active profiles can also be skipped to another step or reverted to a previous step. Please refer to Profiles for a full guide.
The following options are available in the Settings Menu.
To change any of the advanced settings enter the Menu by pressing Select . Once in the menu navigate to Settings and press Select
Up or Down buttons to adjust the set value for the setting. To save your setting hit Select . To return to the menu without saving choose Return
Some options are on/off toggles that can be activated or deactivated from the Settings Menu directly.
Temperature Sensor
Select built-in probe or select any Bonded Bluetooth RAPT Pill & Hydrometer
Show Graph
Toggles display between the graph or a numerical display
Unit System
Toggles between metric or imperial data
Graph zoom level
Select the date range displayed on the graph (default 7 days)
Cooling Hysteresis
Sets the cooling hysteresis (range 0.0°C-10°C, default 1°C)
Heating Hysteresis
Sets the heating hysteresis (range 0.0°C-10°C, default 1°C)
Compressor Cooldown
Sets the minimum compressor delay (Range 0-10 minutes, default 5 minutes)
Mode Switch Delay
Sets the minimum mode switch delay (Range 0-30 minutes, default 15 minutes)
Cooler Enabled
Toggles cooling on or off (when unchecked, the cooling will not operate irrespective of other settings)
Heater Enabled
Toggles heating on or off (when unchecked, the heater will not operate irrespective of other settings)
Bluetooth Enabled
Toggles Bluetooth functionality on or off
Allowed Sensor Diff.
This sets the allowed temperature differential between the built in probe and the current setpoint when using a Bluetooth device for temperature control (range 1°C-50°C, default 5°C). See Bluetooth Operation
Sensor timeout
Sets the timeout if a Bluetooth device drops out (reverts to internal probe) (Range 5-1800 seconds, default 900 seconds)
Sounds Enabled
Toggles device sounds on or off
Calibration Point 1
First Calibration Point (see Calibration)
Calibration Point 2
Second Calibration Point (see Calibration)
Forget Calibration
Deletes saved calibration settings and restores defaults
NTC Beta
Enter the NTC Beta of an external temperature probe. The default is 3950
NTC Ref. Temperature
Enter the NTC Ref. Temperature of an external temperature probe. The default is 298.2
NTC Ref. Resistance
Enter the NTC Ref. Resistance of an external temperature probe. The default is 100000
Relay Cycle Time
Sets the allowed cycle time for PID heating (Range 5-3600 seconds, default 5 seconds)
PID Heating
Toggles PID heating on or off (recommended for advanced users only)
Heat P Coefficient
Enter desired proportional PID coefficient (Default 0.500)
Heat I Coefficient
Enter desired integral PID coefficient (Default 0.0000)
Heat D Coefficient
Enter desired derivative PID coefficient (Default 0.0000)
Forget WiFi Config
Forgets existing WiFi config - useful if you change WiFI networks
Disable WiFi
Disables WiFi (if you wish to not use the RAPT Portal and have only manual control)
Clear Registration
Clears RAPT Portal registration (see Troubleshooting)
Low Temp. Alarm
This is the temperature below which an alarm will sound (default -10°C)
High Temp. Alarm
This is the temperature above which an alarm will sound (default 50°C)
Check For OTA Update
Manually check and download any available firmware updates
Bluetooth needs to first be enabled in the Settings menu (above).
For more information about Bluetooth operation refer to the Bluetooth section.
NOTE: When using a Bluetooth Bonded RAPT Pill Hydrometer as the temperature probe, it is important to place the RAPT Temperature Controller built in robe in the active fermentation chamber/fridge/freezer.
The Diagnostics menu contains information about the RAPT Temperature Controller. This includes such information as current firmware version, Wi-Fi network and signal strength, MAC address and IP address of the device.
The About menu contains information specific to the firmware and software of the RAPT Temperature Controller and associated devices, including but not limited to copyright information, acknowledgment of open source properties used, legal information etc.
To Bond a Bluetooth enabled RAPT devices, use the Up or Down buttons to scroll to select the device. Choose Select button to Bond the device, or the Return button to cancel.
Once Bonded, the device will be visible in the Bonded section of the Bluetooth Menu. To Unbond, select the device with the navigation arrows and choose Select buttont to Unbond the device, or the Return button to cancel.