Bluetooth Operation

RAPT Pill Hydrometer & Thermometer - Bluetooth Operation Guide

Bluetooth Setup and Bonding

The RAPT Pill can send telemetry via WiFI or Bluetooth. For general use WiFi is the default option.

Bluetooth will only work if the RAPT Pill Hydrometer is paired with a Bluetooth capable RAPT device such as a RAPT Fermentation Chamber, a RAPT Temperature Controller or a RAPT Glycol Chiller.

Benefits of Bluetooth Operation

Once a RAPT Pill Hydrometer is set to Bluetooth Telemetry and Bonded with a compatible RAPT device (such as a RAPT Fermentation Chamber or a RAPT Temperature Controller) the Pill Hydromer can be used as a temperature probe for that RAPT device.

This is fantastically powerful.

As well as transmitting temperature information, the RAPT Pill will also send both Gravity and Gravity Velocity to the Bonded RAPT device.

This allows the use of powerful and complex Fermentation Profiles.

For example, you can select to have the temperature maintained until a set gravity is reached. You may prefer to ramp the fermentation temperature when the Gravity Velocity slows to a certain level. This functionality is unlocked via Bluetooth!

To enable Bluetooth on the Pill, you must first connect to the Pill Captive Portal by following the instructions above. Then, navigate to the Settings page of the Captive Portal.

There is a dropdown menu for Telemetry Method. This enables you to switch between WiFi or Bluetooth for telemetry, and also to set the desired telemetry interval.

The default telemetry interval for WiFI is 60 minutes.

The default telemetry interval for Bluetooth is 1 minute

It is not recommended to set shorter telemetry intervals. Shorter intervals will impact battery life.

Recommended telemetry intervals are 60 minutes for Wifi and 5 minutes for Bluetooth – this provides the best combination of accurate reporting and battery life.

Once Bluetooth has been enabled in the Pill Captive Portal, the Pill must be Bonded with a RAPT Bluetooth device such as a RAPT Fermentation Chamber, a RAPT Temperature Controller.

Note: Bluetooth requires a compatible RAPT device such as a Fermentation Chamber or Temperature Controller. Bluetooth will not broadcast unless the RAPT Pill is first registered to the RAPT Portal using WiFi.

When a Pill has been bonded with a compatible RAPT device the RAPT device can then be set to use the Pill as the Temperature Sensor. Doing this allows temperature control using real time telemetry from the bonded Pill. This will also display up to date temperature and gravity data on the RAPT device.

For further information about Temperature Sensor control using a Bluetooth Bonded Pill refer to the Bluetooth section of the relevant device User Manual - or

Standard Calibration

RAPT Pill Hydrometer & Thermometer - Standard Calibration Guide

Standard calibration mode is recommended for most users.

Standard calibration is the quickest and simplest method of calibration.

Enter Calibration mode

  • Plug your Rapt Pill into a charger or computer with a USB-C cable (not included) or place on the wireless charger (if the wireless charging kit is installed)

  • On your smart phone or tablet, open your WiFi settings and connect to the RAPT Pill XXXX access point using the password "kegland1". You may not need to enter the password if you have previously connected your device to the Pill WiFi

  • Once the RAPT Pill Access Portal is open on your phone or tablet, navigate to the Calibration tab

  • Fill a container of sufficient volume to hold the RAPT Pill in suspension with a liquid of known gravity. It is simplest and easiest to use water which has a gravity of 1.000

  • Place the Pill gently into the liquid. Ensure that it can float freely and is not touching the bottom of the vessel, as this will affect the angle

  • Select Standard Calibration in the Pill Captive Portal

  • Enter the known gravity of the liquid - typically 1.00 for water or sanitiser at the correct dilution

Your Pill is now calibrated and ready to use!

  • Wait for the angle reading to stabilise. The angle will never be completely steady, as it is extremely sensitive

  • Hit Calibrate and wait for Calibration to be completed

  • Perform Standard Calibration

    Enable Bluetooth/WiFi

    RAPT Fermentation Chamber
    RAPT Temperature Controller

    Advanced Calibration

    RAPT Pill Hydrometer & Thermometer - Advanced Calibratin Guide

    Advanced calibration mode is suited for higher gravity ferments.

    Advanced calibration mode can give greater accuracy across a wider range. Advanced calibration is also quite quick and easy, and can provide a more accurate result than Standard Calibration.

    It is the same procedure as standard calibration, but in addition to water at 1.000, you need a solution of a known gravity prepared. We recommend using a gravity in the range that your fermentation will start – 1.040-1.060 for typical beers, for example.

    Enter Calibration mode

    • Plug your Rapt Pill into a charger or computer with a USB-C cable (not included) or place on the wireless charger (if the wireless charging kit is installed)

    • On your smart phone or tablet, open your WiFi settings and connect to the RAPT Pill XXXX access point using the password "kegland1". You may not need to enter the password if you have previously connected your device to the Pill WiFi

    • Once the RAPT Pill Access Portal is open on your phone or tablet, navigate to the Calibration tab

    • Fill a container of sufficient volume to hold the RAPT Pill in suspension with a liquid of known gravity. It is simplest and easiest to use water or sanitiser which has a gravity of 1.000

    • Fill another container capable of holding the Pill in suspension with a liquid of known gravity in the range representative of the upper limit of your starting gravity

    • Place the Pill gently into the weaker solution. Ensure that it can float freely and is not touching the bottom of the vessel, as this will affect the angle

    • Select

    Your Pill is now calibrated and ready to use!

    RAPT Pill Hydrometer | User Guide

    KL20596 RAPT Pill Hydrometer & Thermometer | User Guide

    The RAPT Pill Hydrometer and Thermometer allows accurate, real time temperature and gravity logging during fermentation over either WiFi or (with a Bluetooth capable RAPT device) over Bluetooth.

    When integrated with a RAPT device such as a RAPT Fermentation Chamber, the RAPT Pill can be used as a probe that controls your fermentation.

    This opens up a whole world of possibilities! You can use gravity or even gravity velocity as a trigger for temperature increases. No more guessing when its time to do a diacetyl rest - simply set your RAPT device to ramp up the temperature when the gravity change starts to slow down!

    With a easy to clean form factor and a powerful 18650 Li-ion battery, these can last for months between charges.

    We highly recommend the wireless charging kit for the Pill, or a complete Wireless Charging RAPT Pill Hydrometer & Thermometer can be purchased.

    Need more then one Pill! Easy! Grab the colour of your choice - choose either the Red Pill, Blue Pill or Green PIll

    Before using the RAPT Pill Hydrometer & Thermometer for the first time, it needs to be fully charged, updated and registered to the RAPT Brew App.

    To download the RAPT Brew App use these links:

    Calibration

    RAPT Pill Hydrometer & Thermometer - Calibration Guide

    Calibration before first use is strongly encouraged for best results.

    It is recommended to recalibrate after the Pill housing has been opened (to recharge via USB-C, for example), as tiny changes when opening/closing the housing can affect calibration.

    IMPORTANT: The RAPT Pill is designed to disconnect from the RAPT Portal once the USB-C cable is unplugged to preserve battery life. Opening the Calibration or Diagnostics screen before disconnecting will keep the Pill Captive Portal active to allow calibration of the Pill. You will be prompted after 10 minutes to “Click Here To Maintain Connection” if the calibration process takes longer than 10 minutes.

    Once you have entered a Calibration mode, please assemble your Pill according to the so that it can be removed from the USB and calibrated according to the instructions below

    • Plug your Rapt Pill into a charger or computer with a USB-C cable (not included) or place on the wireless charger (if the wireless charging kit is installed)

    Advanced Calibration
    in the Pill Captive Portal
  • Enter the known gravity of the liquid - typically 1.00 for water or sanitiser at the correct dilution

  • Wait for the angle reading to stabilise. The angle will never be completely steady, as it is extremely sensitive

  • Hit Calibrate and wait for the first calibration step to be completed

  • Place the Pill in the stronger solution. Enter the gravity as determined by a calibrated hydrometer. Once the angle reading has stabilised press Calibrate. Wait until the screen indicates that calibration is complete

  • Perform Advanced Calibration

    On your smart phone or tablet, open your WiFi settings and connect to the RAPT Pill XXXX access point using the password "kegland1". You may not need to enter the password if you have previously connected your device to the Pill WiFi

  • Once the RAPT Pill Access Portal is open on your phone or tablet, navigate to the Calibration tab

  • Select the desired calibration method (, or ) and follow the relevant steps

  • How to perform , or calibration on your RAPT Pill Hydrometer

    To enter Calibration mode

    directions
    RAPT Brew on the App Store
    RAPT Brew on the Play Store
    Standard
    Advanced
    Custom
    Standard
    Advanced
    Custom
    Calibration Options

    Registration & Assembly (Legacy Portal)

    RAPT Pill Hydrometer & Thermometer - getting started!

    Setup and Registration

    Register Your Pill Hydrometer

    Ensure you have updated the firmware on your device before attempting to register

    In order to use your RAPT Pill Hydrometer, it must be connected to your WiFI network and registered to the RAPT Portal

    If your Pill is assembled, charged and ready to go, then you just need to connect it to WiFI and Register your Pill to the RAPT Portal. If it is not ready to go, please refer to Setup & Assembly

    Connect your Pill Hydrometer to your WiFi network

    • Plug your Pill Hydrometer into power using using a USB-C cable (not included).

    • OR (Wireless Charging ONLY) Place the Pill on the Wireless Charging base. Note. The battery needs to have sufficient charge to broadcast the Captive Portal when wireless charging is used.

    • On your smart phone or tablet, open your Wi-Fi settings and connect to the RAPT Pill XXX network using the password kegland1

    • Once your smart phone or device is connected to the Pill network, the Pill Captive Portal will open automatically.

    • Select your WiFi network from the list of available networks, and enter the WiFi password for your network then select Join. This will connect your Pill Hydrometer to your WiFi network.

    • Once the Pill is sucessfully connected to your WiFi Network, navigate to the Diagnostics screen in the Pill Captive Portal. Select Check for new firmware. If a newer firmware is available, this will be downloaded and installed.

    • Once your Pill Hydrometer is connected to your Wi-Fi network and the firmware is up to date navigate to the Registration screen in the Pill Captive Portal.

    • A Mac Address and Validation Code will be displayed in the Pill Captive Portal. Write both of these down or ensure that your smart phone screen stays on so that you can acess this information. You will need to enter the MAC address and Validation Code on the RAPT Portal to register your device.

    • Log in to the RAPT Portal (https://app.rapt.io/) on a device that is connected to the same Wi-Fi network as the Pill Hydrometer you are registering.

    If, after troubleshooting, your RAPT Pill is visible in the RAPT Portal but not registered or sending telemetry after at least 60 minutes have elapsed, open the Pill Captive Portal to check Registration status.

    • Open the Pill Captive Portal on your mobile device. Navigate to Registration. If the message reads REGISTRATION DONE! then your RAPT Pill has been successfully registered.

    • If it is displaying the MAC address and Validation Code then registration has not been successful.

    To re-register your RAPT Pill do not delete the device from the RAPT Portal, instead follow the steps below.

    • Reboot the Pill - this forces a new Validation Code to be generated. To 'reboot' simply remove the battery for 30 seconds after unplugging the Pill from USB-C or removing it from the wireless charger. Pills can also be rebototed through the Reboot option in Diagnsotics on the Pill Captive Portal.

    • Connect the Pill via USB-C cable or place it on the charging base (if wireless). Open the Pill Captive Portal on your smart phone or tablet.

    • Navigate to the Registration tab in the Pill Captive Portal. Click the Clear Registration button if displayed, and wait a couple of seconds for a new Validation Code to be generated. Note: If there is no Clear Registration option then the Pill has not been registered to the RAPT Portal and this step can be skipped.

    A guide to assembling and charging your new RAPT Pill Hydrometer and Thermometer

    • Fully Charge the Li-ion battery after installation before first time use by plugging a USB-C cable into the USB-C charging port on the circuit board until the RED charging LED turns off. This allows the device to calibrate and correctly determine the remaining battery charge. The initial charging period is typically around 24 hours.

    • Incorrect battery orientation can damage the circuit board.

    • Always leak test your RAPT Pill by submerging in water prior to sanitising and dropping in your fermenter

    • Only use KegLand approved cleaners such as

    The battery will come pre-installed in the RAPT Pill with a non-conductive strip on each terminal to prevent the device from being activated during transit.

    Before plugging the device into power, you will need to remove the battery and remove the two non-conductive strips from the terminals. Then reinstall the battery making sure you follow the (+) and (-) inscriptions on the battery and battery housing to ensure you install the battery in the correct orientation.

    • REMOVE BATTERY

    • REMOVE BLUE NON-CONDUCTIVE STRIPS

    • RE-INSERT BATTERY (ENSURE CORRECT ORIENTATION)

    Only use KegLand approved 18650 rechargeable Lithium-ion batteries (). If non-approved batteries are used the device will require calibration.

    Once installed ensure your battery has good contact with the terminals. After installing the battery rotate it slightly within the battery holder to ensure it has good contact.

    Important: Once you have installed the Li-ion battery in the correct orientation FULLY charge the battery before first time use by plugging a USB-C Cable into the USB-C Charging port on the circuit board (USB-C cable NOT included).

    Leave the USB-C Cable plugged in for at least 24 hours.

    When installing the circuit board into the housing it is important to insert the circuit board in the correct orientation to ensure the correct weight distribution for accurate readings. The yellow end of the circuit board should be inserted into the yellow housing as shown below.

    Once the circuit board has been inserted into the yellow housing, screw the two housings together hand-tight until both o-rings are hidden to ensure formation of a hermetic seal.

    The housing is typically quite tight, especially when the housing is brand new. A dab of food grade lube on the threads can make the Pill easier to to assemble.

    The RAPT Pill features two onboard LEDs Charging LED (RED)

    • Solid Red when plugged into USB-C – Charging

    • No Red Light when plugged into USB-C – Fully charged

    • Red Light flashing rapidly – battery not inserted/inserted incorrectly

    ESP LED (GREEN) When not connected to USB-C

    • Solid green: will pulse green briefly when sending telemetry/movement detected

    ESP LED (GREEN) When connected to USB-C or charging on the Wireless Charger (sold seperately)

    • Slow green flashes (approx. one every 1.6 seconds): Searching for WiFi network

    • Faster green flashes (approx. 3.2 per second): Connected to WiFi

    • Rapid Green Flashes: Movement detected

    Custom Calibration

    RAPT Pill Hydrometer & Thermometer - Custom Calibration Guide

    Warning! Custom Calibration is for advanced users only.

    Typically Advanced Calibration is accurate enough for all but the most extreme use cases.

    This mode can provide the most accurate readings across a wider range than the other calibration modes.

    Only proceed if you are comfortable with spreadsheets and complex curves. If you are working with solutions with gravities higher than 1.080, then custom calibration is advised.

    For Custom calibration, you will need to take readings at various gravity points roughly 10 gravity points apart, and make a note of the angle of the Pill at each point. We recommend readings from 1.080 down to 1.000, 10 points apart (so, 1.080, 1.070, 1.060 etc). Note that it does not matter if the gravity readings are not exactly 10 points apart, as long as the gravity reading is correct. Use of a hydrometer that is known to be accurate is quite important.

    To perform Custom Calibration, it is easiest to start with the strongest solution and dilute to progressively weaken the solution. It is important to use a calibrated hydrometer to ensure accurate gravity readings

    Enter Calibration mode

    • Plug your Rapt Pill into a charger or computer with a USB-C cable (not included) or place on the wireless charger (if the wireless charging kit is installed)

    • On your smart phone or tablet, open your WiFi settings and connect to the RAPT Pill XXXX access point using the password "kegland1". You may not need to enter the password if you have previously connected your device to the Pill WiFi

    • Once the RAPT Pill Access Portal is open on your phone or tablet, navigate to the Calibration tab

    • Place the Pill in the first solution of known gravity. Wait for the angle to stabilise, then make a note of the angle and the gravity

    • Repeat this step for solutions of different gravity, making a note of the angle and the gravity at each step. It is easiest to dilute the starting solution in steps of approximately 10 points. Finish with a reading in a solution with a gravity of 1.000 (IE water)

    Once you have sufficient readings, the angle and the gravity need to be entered on an Excel spreadsheet (or similar such as Google Sheets) as a graph with gravity on the ‘y’ axis and angle on the ‘x’ axis. The more readings you take, the more accurate this calibration will be. We recommend a minimum of 6 samples, with 10 or more providing a greater degree of accuracy.

    When you have created the graph, create a polynomial trend line onto the graph with the degree of the polynomial being at least one less than the number of data points. If the trend line creates an irregular curve (such as not passing through the data point at 1.000 correctly or not following a polynomial shape) reduce the number of data points (ensuring that there are still more data points than the degree of the polynomial) until the curve matches.

    This is a sample only

    With 10 data points, a polynomial degree between 5 and 8 will typically give the best results.

    Copy the equation of the trend line that is generated once this is done.

    Paste this equation into the field provided on the Custom Calibration screen (In Google Sheets, set your label to Use Equation).

    This will look similar to this:

    y = 0.0000023109x5- 0.0005741632x4+ 0.0568746764x3- 2.8119846525x2+ 71.1087310405x + 265.6578215178 This is a sample only – DO NOT USE THIS EQUATION AS IT WILL NOT BE ACCURATE

    Substitute x in this equation with “angle^” thus:

    y = 0.0000023109angle^5- 0.0005741632angle^4+ 0.0568746764angle^3- 2.8119846525angle^2+ 71.1087310405angle + 265.6578215178

    This is a sample only – DO NOT USE THIS EQUATION AS IT WILL NOT BE ACCURATE

    Paste this equation into the field in your Custom Calibration to complete the calibration.

    Congratulations! Your Pill is calibrated and ready to go.

    Your Pill is now calibrated and ready to use!

    In the RAPT Portal select the button from the menu. Select Pill Hydrometer from the drop down. Select Next after ensuring that your Pill Hydrometer is connected to your WiFi network as above.

  • Enter the MAC address (this will default to All Caps - that is normal) and Validation Code when prompted in the required fields, then select Next.

  • You will be prompted to enter a name for your Pill Hydrometer. This is to identify the device in the RAPT Portal, and does not have any functional effect. Input the desired name and select Finish

  • Check the Registration screen in the Pill Captive Portal. This should now display the following message: REGISTRATION DONE!

  • If this is still showing the MAC address and Validation Code then registration was unsuccesful. Please re-register your Pill using the instuctions below. If that fails, please refer to

  • Congratulations! Your RAPT Pill Hydrometer is connected to WiFi and registered to your RAPT Portal. You can now access telemetry through the RAPT Portal.

  • On a separate device that is connected to your WiFi network, open and sign in to the . If you are already signed in to the RAPT Portal, log out and sign in again - this will force any updates which can help resolve issues.

  • Click on the Edit button of the RAPT Pill that you wish to re-register.

  • Go to the Troubleshooting tab.

  • Click the Reset Device Authentication button.

  • When prompted, enter the new Validation Code that was generated and click Save. Your RAPT Pill should now be registered successfully.

  • and
    and sanitisers such as
    or
    .

    Register your Pill Hydrometer to your Account on the RAPT Portal

    Re-Register your RAPT Pill

    Setup & Assembly

    WARNING

    Battery Installation

    BEFORE CHARGING

    Assembly

    LED Indicators

    KL26734
    Remove blue tabs before charging!
    Battery Terminals
    Correct battery polarity in terminals
    Correct circuit board orientation
    Both O-rings sealing on face of coloured housing

    Perform Custom Calibration

    Custom Calibration - SAMPLE ONLY
    troubleshooting
    RAPT Portal
    StellarOxy
    StellarClean
    StellarSan
    Phosphoric Acid

    Operation

    RAPT Pill Hydrometer & Thermometer - Operation Guide

    Setup and Testing

    After charging, assembly and device registration your RAPT Pill should be calibrated before use. Refer to the Calibration section for instructions on how to calibrate your device.

    1. Calibrate and then assemble your RAPT Pill. After calibration confirm your RAPT Pill is correctly sending telemetry to the RAPT Portal by leaving it in a jug of water or sugar solution for an hour and checking to see if telemetry has been received by the RAPT Portal. It is best to conduct this test in the position where the Pill will be located during fermentation. For example, f you are fermenting in a fermentation chamber place the Pill in a jug in the fermentation chamber to confirm that telemetry is received and your RAPT Pill has good signal strength.

    2. Once it is confirmed that your RAPT Pill is sending telemetry then sanitise your RAPT Pill with an approved sanitiser such as StellarSan or Phosphoric Acid which has been correctly diluted according to the instructions on the sanitiser’s container.

    3. Drop your RAPT Pill into your fermenter to monitor the specific gravity and temperature of your brew in real time

    The RAPT Pill will enter sleep mode when the device is in a horizontal orientation. It will automatically wake up when its orientation is changed indicated by the illumination of a green light on the circuit board. When not in use ensure the RAPT Pill is in a horizontal orientation to ensure it remains asleep.

    When in normal operation the Pill will stay in sleep mode but will 'wake' at the set telemtry interval to send telemetry. This will be visually indicated by the green LED illuminating briefly.

    Your RAPT Pill will automatically check and install for firmware updates when plugged in to USB power with a USB-C cable (not supplied).

    To check the firmware on your Pill, plug the Pill in with a USB-C cable (or place it on the charging base if using the Wireless Charging Kit) then open the Pill Captive Portal by connecting to the Access Point on your phone or tablet or through the Pill IP address.

    1. Plug your Pill in to USB power with a USB-C cable (or place it on the charging base if using the Wireless Charging Kit)

    2. Connect to the Pill Captive Portal with your phone or tablet or through the Pill IP address.

    3. Navigate to the Diagnostics page.

    4. Check that your RAPT Pill is running the latest firmware.

    Use of the with the RAPT Pill is very useful for increasing ease of use and minimising the need to calibrate the Pill after charging, updating firmware etc.

    Once the Complete Wireless Charging Kit or the has been correctly installed (please refer to for an installation guide) then the Pill can be wirelessly charged. You can also purchase the

    Wireless charging also allows for updating the firmware and accessing the Pill Captive Portal without needing to open the Pill housing to plug the Pill into USB-C.

    To charge the Pill simply place it on the wireless charging base, ensuring that the coils are centred over the indicated charging spot on the base. When the Pill is placed on the base the red LED will illuminate to indicate that the Pill is charging. The green LED will start flashing indicating that the Pill is broadcasting a signal so that you can connect to the RAPT Pill XXXX WiFi to open the Captive Portal.

    The RAPT Pill will periodically check for OTA (Over The Air) firmware updates when charging commences, so this is typically all that is required to ensure that your firmware stays up to date

    When the RAPT PIll Hydrometer has been registered to the RAPT Portal, you can create a custom Pill Hydrometer Profile in the RAPT Portal.

    A Pill Hydrometer Profile allows you to receive alerts from the RAPT Pill based on telemtery data.

    Pill Hydrometer Profiles are a way to set up Alerts based on the telemetry recevied from the Pill.

    This is extremely useful, especially if you are not using the Pill Hydrometer in conjunction with another RAPT device.

    RAPT Pill Hydrometers will measure temperature, gravity and gravity velocity (rate of change of gravity over a specified interval).

    You can set up alerts based on any of these.

    For example, you can set an alert for when the gravity drops to (for example) 1.025 at which point you may wish to raise the fermentation temperature for a diacetyl rest.

    You can set an alert for the gravity velocity to drop to 0, at which point fermentation is likely finished and you can begin a cold crash.

    You can set an alert when:

    • The temperature reaches {a specified temperature} - select the operator Less Than or Greater Than and Input a Temperature and Alert Message

    • The gravity reaches {a specified gravity} - select the operator Less Than or Greater Than and Input a Specific Gravity and Alert Message

    • The gravity velocity is greater/less than the specified valuereaches {a specified temperature} - select the operator Less Than or Greater Than and Input a Gravity Velocity (in points per day, where one Point = 0.001 sg) and Alert Message

    To receive alerts on your mobile device, you must have the or app installed.

    In order to receive alerts you need to select Enable Mobile App (Push) Notifications in the My Account settings in the RAPT Portal. You must also enable notifications for the Google Play or App Store App on your mobile device.

    Once you are happy that all the Alerts are correct, make sure you hit the Save button to save the profile to your My Profiles library. You can then send it directly to your RAPT device using the Send Profile to Device button or using the Play button in the Dashboard to start a new profile!

    The RAPT Pill Hydrometer & Thermometer can be cleaned with standard cleaning agents such as and . Rinse thoroughly after cleaning and keep contact time to 30 minutes or less.

    Acid based sanitisers such as acid based sanitiser are ideal for sanitising the RAPT Pill Hydrometer & Thermometer. It is best practice to immerse the RAPT Pill Hydrometer & Thermometer in StellarSan diluted to the correct ratio immediately prior to adding the Pill to the fermenter. It is important to not allow an acid based sanitiser to dry on the Pill as the water content will evaporate leaving concentrated acid which can damage the housing.

    If a firmware update is available, this will be updated automatically when the Pill is plugged in to USB with a USB-C cable (not supplied) or placed on the Wireless Charger (purchased separately).

  • To check and update manually in the event that this is not up to date, select Check for new firmware. Your device will automatically download and update the most current available firmware.

  • Sleep Mode

    Updating Firmware

    Complete Wireless Charging Kit

    Sessions

    Cleaning & Sanitising

    Warning: Do not use alcohol based cleaners or sanitisers over over 20% ABV (such as Ethanol 70% spray, Isopropyl etc). High ABV alcohol based cleaners and sanitisers can cause discolouration and crazing of the clear Nylon 12 Pill housing.

    KL31936 Complete Wireless Charging Kit
    KL32452 Barebones Wireless Charging Kit (Coil and Weights only)
    this video
    KL35910 Pre-assembled Wirelessly Charged RAPT Pill
    Google Play
    Apple App Store
    StellarClean PBW
    StellarOxy
    StellarSan

    RAPT Pill Captive Portal

    RAPT Pill Hydrometer & Thermometer - Captive Portal Guide

    Overview

    The Rapt Pill Captive Portal can only be accessed when the RAPT Pill is plugged in to USB-C or (Wireless Charging ONLY) charging on the Wireless Charging base. Note. The battery needs to have sufficient charge to broadcast the Captive Portal when wireless charging is usedYou can access the Captive Portal in two ways. You can connect directly to the Pill’s WiFi using a phone, tablet or computer. Simply connect to the Pill’s WiFi network (the network name will be in the form RAPT Pill XXXX where the last 4 digits correspond to the last digits of the Pill’s MAC address).

    Alternatively, once the Pill has been connected to your WiFi network, you can access the Captive Portal by entering the Pill’s IP address on a browser. The IP address can be found in the Diagnostics screen of the Captive Portal.

    Note: The Pill Captive Portal will close automatically after 10 minutes when the Pill is plugged in to USB-C. If the Pill is disconnected from USB-C within 10 minutes the Pill Captive Portal will close.

    This is by design to maximise battery life.

    To keep the Captive Portal open for up to 10 minutes while disconnected from USB-C (for example, in order to perform calibration of the Pill) you must first open the Diagnostics or the Calibration screen of the Pill Captive Portal.

    There are five options available in the Captive Portal.

    • CONNECTED TO: This displays the WiFI Network the RAPT Pill is currently connected to

    • MANUAL CONNECT: This allows you to input a (hidden) SSID (if your network is hidden or private, for example)

    • OR CHOOSE A NETWORK: You can select any visible WiFi network top connect the RAPT Pill to

    The Registraion screen will display the Pill's MAC Address and Validation Code (if the Pill is connected to WIFI but not registered) or REGISTRATION DONE (as above) if the Pill is sucessfully registered to the RAPT Portal.

    • Telemetry method - select either WiFI or Bluetooth

    • Telemetry interval - set the desired inteval for telemetry

    • Gravity velocity measurement time - select the period over which gravity velocity (rate of change of gravity) is measured. We recommend 1 day for meaningful results

    • Temperature offset - set the offset (up to +/- 10°C) if the on board thermeometer needs calibrating*

    *The RAPT Pill temperature reading will usually be high during Captive Portal access, charging or calibration. This is because the Li-ion battery can generate quite a bit of heat in sustained use.

    SENSOR VALUES

    • Accelerometer X/Y/Z: current accelerometer reading

    • Tilt Angle: current tilt angle

    • Specific Gravity: current gravity reading

    • ADC2: current ADC2 (analogue to digital) reading

    *not displayed until battery is calibrated ** typically not accurate when Pill Captive Portal is open, as the battery generates heat when charging *** Will display 0.0.0.0 if the Pill is not connected to WiFI

    GRAVITY VELOCITY

    • Valid: true or false

    • Gravity velocity: current gravity velocity

    • Age of latest: last gravity velocity reading telemetry reading

    • Dataset size: number of data points

    ACTIONS

    • Send telemetry now - manually send telemtry to the RAPT Portal

    • Check for new firmware - check for firmware updates

    • Send diagnostics log - send diagnostic data (only at the request of help desk)

    • Reboot device - reboots RAPT Pill (useful if you ahave WIFI connectivity issues)

    In this screen you can perform , or calibration. You can also Clear an existing calibration.

    Troubleshooting

    RAPT Pill Hydrometer & Thermometer - Troubleshooting Guide

    Problem
    Solution

    Battery: current battery charge level*

  • Temperature: current temperature**

  • Firmware: current firmware version

  • MAC address: Pill MAC address (required for Registration)

  • IP (STA): IP address (static)***

  • IP (AP): IP address (access point)

  • Telemetry sent XX/YY: telemetry sent(XX) / telemetry recevied (YY)

  • Oldest item: oldest reading

    Factory reset - restores Pill to default factory settings. Warning - clears WiFI and Registration settings

  • Get gravity data - downloads .csv of gravity data

  • WiFi

    Registration

    Settings

    Diagnostics

    Calibration

    Standard
    Advanced
    Custom

    Select RAPT Pill XXXX network

    Enter password 'kegland1'

    Plug the Pill into USB-C or place on wireless charger (if using the wireless charging kit)

    If the green LED is not flashing, unplug the Pill for 20 seconds and plug it back in (or place back on charger)

    Cannot see RAPT Pill XXX in my list of available networks

    Plug the Pill inot USB-C or place on wireless charger (if using the wireless charging kit)

    If the green LED is not flashing, unplug the Pill for 20 seconds and plug it back in (or place back on charger)

    If the above do not work, reboot the Pill by removing the battery for 30 seconds, then plugging it back into USB-C

    If using the wireless charging kit, the Pill Captive Portal cannot be accessed unless the Pill has a minimum charge level. It must be charged for at least 12 hours on first use

    "Selected Network is not connected to the Internet" error

    Select the RAPT Pill XXX network and choose "Forget This Network"

    Pill does not connect to my WiFi network

    Check that your network is broadcasting a 2.4gHz signal and ensure that the Pil is as close as possible to the router

    Non alphanumeric characters in the SSID or password can cause issues - change these to simple (letters and numbers only) characters

    Ensure you are selecting the correct network and inputting the correct password for that network

    The network must have a password – the Pill cannot connect to an unsecured network

    The Pill may already be connected. Check the IP (STA) in Diagnostics. If this is populated with an IP address that is not 0.0.0.0 then the Pill is likely already connected

    Open Diagnostics in the Pill Captive Portal and select Reboot

    Reboot your modem/WiFi router

    Reboot the Pill using Reboot option in DIagnostics screen in the Captive Portal

    Try connecting to a different WiFi network

    Turn off any VPN or anything that can block an outgoing signal on the router

    If the above do not work, see below

    Cannot see a Validation Code

    Connect the Pill to your WiFi network

    Update the Pill firmware - select Check for new firmware in the DIagnostics screen

    Error when Registering Pill

    Check that the Pill Firmware is up to date - select Check for new firmware in the DIagnostics screen

    The Validation Code may have timed out. Reboot the Pill using the Reboot option in the Diagnostics screen. Log out of the RAPT Portal and log back in

    Ensure the RAPT Portal is open on a device connected to the same network as the Pill. If the Pill Captive Portal is open on the device, it is not connected to the internet and Registration will not work. Open the RAPT Portal on a seperate device such as a laptop or tablet

    Determine whether your RAPT Pill is connected to Wi-Fi

    To check this, plug your RAPT Pill in to power and open the RAPT Pill Captive Portal and Navigate to WiFi. It will display the network the Pill is currently connected to. You can also check by navigating to Diagnostics and checking that it shows your network’s IP address next to IP (STA) - in the form 192.168.XX.XXX or similar

    Determine whether your RAPT Pill is registered to the RAPT Portal

    Open the Pill Captive Portal on your mobile device. Navigate to Registration. If the message reads REGISTRATION DONE! then your RAPT Pill has been sucessfully registered. If it is displaying the MAC address and Validation Code then registration has not been sucessful - see Re-Register my Pill below

    Re-register my RAPT Pill

    Refer to

    Telemetry is only received when the Pill is powered by USB-C

    Ensure you have updated to the current firmware

    Check that the battery is making good connection with the battery terminals of the Pill’s board. It may be necessary to gently bend these out in order to ensure the battery is making good contact in order to power the Pill when it is not connected to USB-C

    No telemetry displayed in the RAPT Portal

    Telemetry will take at least 60 minutes to display. If the message Last Contact: never is still di[played in the Pill Status after at least 60 minutes, your Pill to correct this

    Check that the Pill is Registered. Plug your RAPT Pill in to power and open the RAPT Pill Captive Portal and Navigate to Registration. If Registration has been successful this will display the message REGISTRATION DONE! If registration was not successful then this will display the MAC Address and Validation Code. your Pill to correct this

    Check that your Pill is connected to WiFi in the Pill Captive Portal. Plug your RAPT Pill in to power and open the RAPT Pill Captive Portal and Navigate to Wi-Fi. Check that it shows that the RAPT Pill is connected to your home Wi-Fi network

    Check that the Pill firmware is up to date.

    Connect to the Pill Captive Portal and navigate to the Diagnostics screen. Select Check for new firmware. If a more up to date firmware is available this will be downloaded and installed

    Check your signal strength. Please refer to the . Signal Strength can be checked in the expanded graph in the RAPT Portal

    Battery % shows 0 or no value

    The battery is not calibrated yet. The battery must be charged completely for the Pill to calibrate the battery charge level. If the battery was fully charged but not calibrated simply let the battery drain (easiest to just use the Pill as intended). Then, recharge the battery fully. This will allow the Pill to register the fully charged battery. This can happen if it is removed from the charger before the Pill has registered the calibration state

    Clear housing discoloured, crazed or has hairline cracks

    Probable exposure to high percentage alcohol, ethanol or isopropyl. Do not use high ABV sanitisers or cleaners on the clear Pill housing (over 20% ABV) as this can degrade Nylon 12

    Signal Strength Graph

    If updating the firmware persistently fails or throws an error, and all troubleshooting steps have failed, then try using your mobile phone as a Hotspot to resolve this.

    Using the phone as a Hotspot will typically solve firmware update issues of this kind

    1: It helps eliminate potential network or modem/router issues which can cause problems that can be hard to isolate and resolve

    2: It can help eliminate signal strength or poor WiFi connection issues as the phone can be positioned right next to the RAPT device when in Hotspot mode.

    To connect to the phone Hotspot and update the firmware there are a few steps to follow

    1. On the phone, turn WiFi OFF. When troubleshooting firmware download or network issues, we do not want to use the same network thus the phone must be disconnected from the WiFi network in order to do this

    2. Enable Personal Hotspot (sometimes just called Hotspot) on your phone. This is typically located under the WiFi or Network menu in the Settings menu of the phone. On IOS this is under Settings/Personal Hotspot. The menu names will vary on Android depending on device

    3. Enable Maximise Compatibility (on IOS) or 2.4gHz Network Only (on Android - again, this will have different names depending on device/OS). This will help minimise issues when connecting

    4. Once Hotspot is enabled on the device, following the steps in to connect to the phone Hotspot

    5. Once connected, navigate to Settings/Check for OTA update on the RAPT Device

    Problem
    Solution

    Red (battery) light flashes very rapidly when plugged in to USB-C

    Please install the battery or check that it is making good contact with the terminals

    Lights turn off immediately when disconnected from USB-C

    This is normal. To conserve battery power, the Captive Portal will disconnect as soon as the Pill is unplugged from USB-C

    The RAPT Pill Hydrometer & Thermometer comes with a 12-month Warranty when sold in Australia.

    Warranty does not cover product failure as a result of installation or operating procedure not in accordance with installation and operating guidelines as described in the instruction manual.

    To lodge a warranty claim in Australia please forward as many visual pieces of supporting information and a detailed description of your issue to beer@kegland.com.au

    If you purchased your unit from an international distributor, you will be required to go through their warranty claims process.

    For a full terms and conditions, please visit our website: Terms & Conditions

    Cannot open Pill Captive Portal

    Check that WiFi is active on your mobile device

    Wifi, Registration and Telemetry Issues

    Signal Strength

    Using Phone as Hotspot

    General Troubleshooting

    Warranty

    Pill Wireless Charger Upgrade - Installation

    Pill Hydrometer Wireless Charger Upgrade | Instruction Sheet

    This new wireless charging upgrade enables you to charge the pill hydrometer without the need for open and closing the housing.

    Upgrading to wireless charging is a significant upgrade to the pill hydrometer as it means the pill hydrometer doesn’t require repeated opening and closing and this has several advantages including:

    1. It reduces the chance of damaging one of the two o-rings giving you a more reliable seal

    2. It eliminates the chance that the housing is done up to a different torque resulting in less accurate results

    3. It make charging easier and more convenient

    4. You can now access the Pill Captive Portal without needing to open the housing. This is much more convenient and also negates the need to re-calibrate the RAPT Pill Hydrometer every time you assess the Pill Captive Portal

    1

    Open the pill housing and remove the 5 gram weight from the bottom of the pill and replace it with the 3.5 gram weight. Repeat this process for the weight at the top of the board.

    2

    After the weights have been replaced, attach the two adhesive spacers to the weight at the bottom of the board. stick the wireless charging ring to the base of the pill.

    The order is: Weight: Solid piece: Half moon piece: Charging coil. The cutout of the half moon piece should align with the cutout of the board.

    Ensure this is installed at the centre of the PCB board so it doesn’t get crushed when the pill housing is closed again.

    IMPORTANT NOTE: To access the Pill Captive Portal when the Wireless Charging Kit is installed simply place the Pill on the charging base. If the Pill is already charging, remove the Pill from the charging base and place it back on after 10 seconds.

    If the Pill Captive Portal cannot be ccessed (the green LEDs do not flash and the Captive Portal cannot be seen as a WFi Network, the battery may be at too low a charge level.

    The 18650 Li-ion battery needs a minimum charge level to access the Pill Captive Portal when using the wireless cahrger. Leave the Pill to charge for at least 12 hours before trying to access the Pill Captive Portal.

    Once installed, check that everything is aligned as in the image below.

    3

    Plug the USB type C cord into the Type C socket on the PCB board

    4

    Reinstall the 18650 Li-ion battery, ensuring correct polarity (if removed). Place the pill PCB board and charging coil into the housing ensuring the wireless charging coil sits in the centre of the housing as shown below.

    Tighten the housing until the bottom o-ring is covered to ensure a hermetic seal is formed.

    5

    Close the housing back up and then perform Calibration process. We highly recommend using the Advanced (2-point) calibration process once the wireless charging coil has been put into the housing.

    The easiest way to do this is right before a brew.

    Simply put the pill into 20°C sanitiser solution and calibrate the first point at 1.000 gravity then put the pill into your unfermented wort and calibrate at the known starting gravity (use a second, calibrated hydrometer to complete this calibration process).

    Refer to for a detailed guide to , and Calibration

    Install Pill Hydrometer Wireless Charger Upgrade

    Video Guide

    Replace weights

    Attach wireless charging ring

    Positioning of weights and spacers | Wireless Upgrade Kit
    Correct order for weight and spacers | Wireless Upgrade Kit

    To keep the Captive Portal open, you must first open either the Diagnostics or the Calibration screen of the Pill Captive Portal before disconnecting the Pill from USB-C. The Captive Portal will timeout automatically after 10 minutes

    If the Pill disconnects despite the Diagnostics or Calibration screen being open, please check the charge level of the battery – it may be insufficient to power the Pill. The battery may be faulty, or not making good connection to the terminals. A fully charged battery has around 4.2V – this can be tested with a multimeter

    If the battery has a good charge level but is not powering the Pill it may be necessary to gently bend the terminals out in order to ensure there is good contact with the battery

    Battery level reads 0% or not displaying in the RAPT Portal

    This indicates that the Pill has not detected a fully charged battery. Note that the battery must be charged in the Pill for this to be detected the first time

    Ensure the RAPT Pill is successfully registered to your RAPT login (the calibration figure will not work unless the pill is linked with your RAPT account)

    Discharge the battery by using the RAPT Pill for at least 1-2 weeks or by removing the battery and discharging in a device that uses power faster, then plug the pill into the USB Type C charging cable for 24 hours. This will allow the Pill to register a fully charged battery which enables accurate battery life data to be displayed

    The lights on the Pill stop flashing when it is unplugged

    This is normal. The Pill will be ‘asleep’ by default and will wake briefly at the set interval to send telemetry. The green light will flash when this happens. It may also wake when movement is detected

    Gravity reading is not correct

    Check calibration

    Physical factors can affect accuracy - gently shake the fermenter to dislodge stuck krausen etc

    Ensure the Pill can float freely and unobstructed

    Temperature is incorrect

    Calibrate temperature

    The temperature reading will typically be high when the Pill is active - for example, plugged in to USB-C, charging or during calibration. This is because the battery generates enough heat to affect the on board thermometer. When in normal use, this is not an issue as the Pill will only be active for a few seconds in order to send telemetry.

    Getting Started
    Using Phone as Hotspot
    Re-Register My RAPT Pill
    Re-Register
    Re-Register
    SIgnal Strength Graph below
    Calibrate temperature offset

    Plug in USB-C cord

    Install Board into housing

    Calibrate Pill

    Calibration
    Standard
    Advanced
    Custom
    Correctly Installed | Wireless Charging Kit
    USB-C Socket | Wireless Charging Kit
    Pill Wireless Charging Installation Guide
    RAPT Pill Captive Portal % Registration
    Setting up Bluetooth Bonding and Pairing with a RAPT device