RAPT Temperature Controller | User Guide

KL22927 | KL30410 RAPT Temperature Controller | User Guide

Convert any fridge into a fully featured RAPT fermentation chamber by adding a RAPT Temperature controller.

With all the power and fucntionality of the RAPT Fermentation Chamber, simply plug the RAPT Temperature Controller into your fridge and heat source, and unleash the power of fully integrated RAPT control on your beer!

Easily create complex and powerful fermentation profiles. Add a RAPT Pill Hydrometer to the mix for the very last word in powerful temperature control - there's simply no easier way to make great beer.

The innovative design enables you to panel mount this controller, mount to a hanging point or hook, mount on top of a fridge or brewery. Simply unscrew the mounting plate and switch the mounting to your preferred orientation.

Get Started!

RAPT Temperature Controller - getting started!

Ensure you have updated the firmware on your device before attempting to register

Connect your RAPT Temperature Controller to your WiFi network

  • Register your RAPT Temperature Controller to your Account on the RAPT Cloud

    Setup

    Setting up the RAPT Temperature Controller

    Display Legends

    Graph Disabled Display Legend

    This is the default display. This displays the current temperature and setpoint, as well as useful information such as Heating or Cooling Mode, WiFi and/or Bluetooth This will show an interface like the following:

    Display - Graph Disabled

    Graph Enabled Display Legend

    This displays a graph of temperature vs time with a default period of 7 days. This can be changed by selecting the Show graph checkbox in the Settings. This will show an interface like the following:

    Display - Graph Enabled

    Display Icon Legend

    ICON
    MODE
    FUNCTION

    The RAPT Temperature Controller offers a number of different mounting options offering the versality to be able to change how to controller is mounted depending on what you are using the controller for. The controller is provided as standard with a mounting plate which is installed onto the controller out of the box. This mounting plate can be removed if you would instead prefer to mount the controller onto the wall for example.

    To remove the mounting plate, slide the mounting plate down towards the bottom of the controller.

    If you prefer to mount the RAPT temperature controller to your wall however you did not want to damage the wall by screwing into it you can attach the mounting plate to the wall using strong double-sided tape and then slide the RAPT temperature controller onto the mounting plate to secure it.

    Screw two screws into the wall using the following template as a guide. Then simply hook the controller onto the screws using the mounting points provided on the back of the controller.

    Please use this link to download and print the

    Unscrew the hanging hook and rotate it 180 degrees, retighten and attach the controller to the wall using this hanging hook. This can be mounted to your wall using a screw or hanging the controller onto a hook which is already mounted on your wall for example

    Another option for mounting the RAPT Temperature Controller onto a wall is to drill a screw through the recessed holes below the front face plate which continue all the way through to the two mounting holes at the back of the controller.

    These holes can be identified by running your finger along the face plate in the area shown below. You can then either peel away the face plate and use an 8G x 60mm countersunk screw or you can drill straight through the face plate using an 8G x 60mm or 10G x 60mm countersunk screw as shown below:

    WARNING: Ensure the temperature controller is unplugged from the wall socket before changing the orientation of the cables

    If you want to neatly mount the RAPT Temperature controller vertically onto your bench or into a custom designed cabinet/panel for example, the orientation of the cables can be quickly and easily rearranged. To achieve this, undo the 4 screws which hold the front and back housings together and then pull the two housings apart.

    Unscrew the two screws which hold the slotted blanking plate to the housing and remove the slotted blanking plate.

    Move the cable glands to the back of the unit and secure in place with the slotted blanking plate, then secure the slotted blanking plate to the housing using the two screws. Then reassemble the front and back housings and secure with screws

    You can then custom design your own panel or cabinet to mount this temperature controller into with the outlets and wiring now exiting out the back of the controller allowing for a very neat mounting arrangement.

    Alternatively, if you want to mount this on your bench top or on top of your Temperature Controller you can use the mounting plate as a stand to keep the temperature controller in an upright position. Simply slide the temperature controller housing onto the guides on the mounting plate as shown:

    The RAPT Temperature Controller comes as standard with a 2m extension temperature probe. This probe is calibrated out of the box. You may wish to calibrate this for a number of reasons such as to improve accuracy around the temperature range in use, or if you have replaced the original temperature probe for any reason.

    To calibrate the temeprature probe:

    1. Enter the menu by pressing Select

    2. Set up two glasses of water. Ice water to one glass and add hot water to the second glass

    3. Use the Up or Down arrows to navigate to Settings and press Select

    Insert the temperature probe of the RAPT Temperature Controller into the glass of ice water while simultaneously measuring the temperature of the ice water using a calibrated external thermometer such as a digital instant read thermometer (KL23320). Wait for the temperature reading on both the RAPT Temperature Controller and the external calibrated thermometer to stabilise as much as possible.

    Then adjust the temperature shown on the RAPT Temperature Controller to match the temperature measured on the external calibrated thermometer.

    Press Select to lock in Calibration point 1 and move on to Calibration point 2.

    Insert the temperature probe of the RAPT Temperature Controller into the glass of hot water while simultaneously measuring the temperature of the hot water using a calibrated external thermometer. Wait for the temperature reading on both the RAPT Temperature Controller and the external calibrated thermometer to stabilise as much as possible.

    Then adjust the temperature shown on the RAPT Temperature Controller to match the temperature measured on the external calibrated thermometer.

    Press Select to lock in this calibration point 2

    Alternatively, Bonding a via Bluetooth and using this as the tmperature probe is ideal as this unlocks the ability to have powerful, customised Fermentation Profiles with steps that can be triggered by temperature, time, gravity and rate of change of gravity!

    In the event that you revert back to the standard probe that is preinstalled in the RAPT Temperature Controller, you can manually reset the temperature probe to the default settings.

    1. NTC beta: 3950

    2. NTC ref. temperature: 298.2

    3. NTC ref. resistance: 100000

    You can also select Forget Calibration in Settings. This will revert any saved calibration settings to default.

    Operation

    Operating the RAPT Temperature Controller

    Using the Digital Controller

    The Digital Controller has 4 buttons which serve different functions depending on context

    Cycle/Back - navigation between On Screen options. Exit without saving. Hold when prompted to advance Profile steps

    Select - Select the current option. Enter a Selection. Confirm a choice

    Up - Increase hightlighted variable

    Down - Decrease hightlighted variable

    Manual Operation of the RAPT Temperature Controller

    If you do not intend to connect your device to the RAPT Portal and hence do not want to utilise the WiFi functionality you can operate the Temperature Controller completely manually via the buttons on the display.

    To remove the prompt requesting you to register your device to the RAPT Portal you will need to disable Wi-Fi in the settings. To do this press Select to enter the menu, then select Settings, then navigate using the arrows to the Disable Wi-Fi setting. Press Select to disable the Wi-Fi and the controller will then restart automatically.

    If you decide you don’t want to register your RAPT Temperature Controller to the RAPT portal and hence not use the Wi-Fi functionality of the controller you will in turn lose a lot of the functionality of the controller which is offered through the RAPT Portal. This includes features such as setting up complex temperature profiles which are run automatically and logging past temperature profiles.

    At the home screen press the Up or Down buttons to adjust the target temperature. The Temperature Controller will then automatically send power to the heating or cooling terminals to power on your heating or cooling device to maintain this target temperature.

    NOTE: This is possible only if the device is not currently running an assigned profile.

    The WiFi connectivity of the RAPT Temperature Controller allows you to monitor, track and start a complex temperature profile involving multiple steps remotely through the RAPT Portal. In order to fully utilise the capabilities of this device you should connect your RAPT Temperature Controller to your Wi-Fi network and register it to your account on the RAPT portal at

    This will allow you to track and monitor your fermentation in real time remotely without needing to walk over to your Temperature Controller. It also allows you to setup and send complex fermentation profiles involving multiple steps to your RAPT Temperature Controller which will then automatically run through this profile and adjust the set temperature as required.

    In order to have access to this WiFi functionality you will need to sign up for a RAPT Account, connect your RAPT Temperature Controller to your WiFi network and register your device on your account on the RAPT Portal by following the

    Other Settings that can be adjusted directly in the RAPT Portal include Heating and Cooling On or Off, Heating and Cooling Hysteresis, Fan and Light operations/modes, Compressor and Mode Switch Delay and Telemetry Frequency.

    To access these Settings in the RAPT Portal select the Edit button for your RAPT Fermentation Chamber in the RAPT Portal.

    The temperature set point can also be set through the RAPT Portal or a profile session can be started from the RAPT Portal which will automatically begin the profile you have created.

    To change the temperature set point in the RAPT Portal simply enter the desired Set Point target and press Set

    Once you have registered your RAPT Temperature Controller on the RAPT Portal you can then log telemetry from the device and set up complex temperature/fermentation profiles involving multiple steps.

    To setup a fermentation profile on the RAPT Portal select My Profiles and then Create New Profile. Then add your fermentation profile steps such as primary fermentation, diacetyl rest, dry hop, cold crash etc.

    For a detailed guide on creating complex and powerful profiles please refer to

    Your RAPT Temperature Controller will automatically check for and install firmware updates when turned on and connected to a WiFi network.

    To check the firmware version on your RAPT Temperature Controller, press Select to enter the menu and then navigate to Diagnostics.

    To manually update the firmware in the event that this is not up to date, navigate to Settings and then navigate to Check for OTA Update. Your device will then automatically download and update the most current available firmware.

    NOTE: You must be running the latest firmware in order to register your RAPT device

    Setting the Target Temperature Manually

    Operation of the RAPT Temperature Controller Throught the RAPT Portal

    Setting the Target Temperature via the RAPT Portal

    Updating Firmware

    https://app.rapt.io
    setup instructions
    Creating and Editing Profiles

    HeatingRelay Start Delay

    Connected

    WiFi Connected

    Enabled

    Bluetooth Enabled

    Enabled

    PID Heating Enabled

    Enabled

    Profile Running

    Enabled

    Alarm

    Navigate to Calibration Point 1 and hit Select

    On

    Cooling Relay On

    On with countdown overlay

    Cooling Relay Start Delay

    On

    Heating Relay On

    Mounting the RAPT Temperature Controller

    Removing the Mounting Plate

    Wall Mounting Option 1

    Wall Mounting Option 2

    Wall Mounting Option 3

    Wall Mounting Option 4

    Vertical Bench/Panel Mounting

    Temperature Probe Calibration

    Calibration Point 1

    Calibration Point 2

    Reset Temperature Probe Calibration

    RAPT Temperature Controller Drill Mounting Template
    RAPT Pill Hydrometer

    On with countdown overlay

    Profiles

    Profile User Guide | RAPT Temperature Controller

    Profiles are a key component of the RAPT system. Profiles are powerful tools that can be customised to a great degree, allowing extremely fine control over all aspects of brewing/fermentation

    Profiles are created in the. There are also Global Profiles that can be imported and customised. Once a profile is created in the RAPT Portal, it can be sent to the corresponding RAPT device using Send Profile To Device from the My Profiles screen. Alternatively, you can select Start Profile Session for the RAPT Temperature Controller in the Dashboard. This will send the Profile to the device and also begin the Profile automatically.

    The RAPT ecosystem is intended to be largely controlled remotely, and thus there are more powerful controls in the RAPT Portal than on board the RAPT Temperature Controller.

    Once you have registered your RAPT Temperature Controller on the RAPT Portal you can then log telemetry from the device and set up complex temperature/fermentation profiles involving multiple steps.

    Bluetooth

    Bluetooth Guide | RAPT Temperature Controller

    Bonding a RAPT Pill to send telemetry is a powerful and robust way to really leverage the versatility of the RAPT ecosystem.

    Please refer to this video for a detailed guide to Bonding your RAPT Pill to your RAPT Fermentation Chamber or Temperature Controller.

    , it can be selected in the Settings menu as one of the available Temperature Sensors. Once selected in this menu, temperature control will be ceded to the selected Bluetooth enabled RAPT device, rather than the internal temperature probe. In addition, on the TFT display the current (most recent) Graity and Temperature reading will be displayed. The internal (built in probe) temperature is also displayed. NOTE: this is not displayed in Graph Enabled Mode.

    Once the Pill has been Bonded and selected as the Temperature Sensor of the device, powerful Profile features are unlocked.

    You can set triggers such as Gravity or Gravity Velocity, as well as Time for your fermentation control.

    To setup a fermentation profile on the RAPT Portal select My Profiles and then Create New Profile. Then add your fermentation profile steps such as primary fermentation, diacetyl rest, dry hop, cold crash etc.

    For a detailed guide on creating complex and powerful profiles please refer to Creating and Editing Profiles

    To store a Fermentation Profile on the RAPT Temperature Controller you can select Send Profile To Device from the My Profiles screen. The Profile will be uploaded to the device and can then be started manually on the RAPT Temperature Controller.

    Alternatively, you can select Start Profile Session for the RAPT Temperature Controller in the Dashboard of the RAPT Portal. This will send the Profile to the device and also begin the Profile automatically.

    Note: You cannot create a Fermentation Profile on the RAPT Temperature Controller itself. It must be created in the RAPT Portal first.

    Note: If any changes are made to a Fermentation Profile once the Profile has started these will not be uploaded. You must stop the Profile on the device and restart it in order to have changes reflected on the device.

    To stop running or to pause the Fermentation Profile on the device press Select to enter the Profile Menu. In the Profile Menu use the Up or Down buttons to navigate to and Select either Pause this profile or End this profile.

    To start a profile that has been uploaded to the RAPT device select PROFILES from the main menu.

    This will display a list of Profiles that have been uploaded to the device. Navigate to the desired Profile using the Up or Down buttons and hit Select

    This gives the option to Start Profile Now, Start Profile Later, View Profile or Delete Profile.

    Note: Delete Profile deletes the Profile from the device only. It does not delete the Profile from the RAPT Portal.

    Selecting Start Profile Now will automatically download any updates or changes that have been made to the selected Profile in the RAPT Portal and then begin running the Profile on the device.

    Selecting Start Profile Later will automatically download any updates or changes that have been made to the selected Profile in the RAPT Portal. You will then be taken to the Delayed Start screen where the desired Start Time for the Profile can be selected.

    Once entered, the Profile will begin automatically at the selected Start Time.

    Selecting View Profile will show the Profile Steps before the Profile is started.

    Alternatively, you can select Start Profile Session for the RAPT Fermentation Chamber in the Dashboard of the RAPT Portal. This will send the Profile to the device and also begin the Profile automatically.

    When a Profile is running on the device, each step of the Profile can be viewed in the Profiles menu of the device.

    The Profile can be controlled directly. You can Pause or Stop the currently active Profile.

    Using the Up or Down buttons, you can navigate to each step in the currently active Profile.

    Selecting a Profile step will commence that step unless it is already active.

    Selecting a Profile step may also show other opptions depending on the nature of the Profile step. For example, selecting a Profile step with a duration timer will bring up a slider that allows you to choose the point at which to begin the step. These options are dependant on the type of Profile step being selected.

    To stop running or to pause the Fermentation Profile on the device press Select to enter the Profile Menu.

    In the Profile Menu use the Up or Down buttons to navigate to and Select either Pause this profile or End this profile.

    Pause this profile will stop the current profile until it is started again in the Profile menu

    Stop this profile will stop the profile

    Creating a Fermentation Profile on the RAPT Portal

    RAPT Portal

    Storing a Fermentation Profile on the RAPT Temperature Controller

    Starting a Profile

    Controlling a Profile

    Stopping a Profile

    For example, instead of setting a fairly arbitrary length of time before you start ramping the temperature of your fermentation for a diacetyl rest, you can choose a specific gravity point or (even mrore acurately) a specific Gravity Velocity (rate of change of gravity) as a trigger point for increasing the temperature.

    A common Fermentation Profile involves maintaing temperature for three days, and then increasing the temperature as the Gravity Velocity slows down, and then again when the Gravity Velocity slows further, signalling that fermentation is nearly done. This type of profile can work (with slight variations) for nearly every yeast, and allows us to maintain optimum yeast health and activity for a fast but clean fermentation!

    This Sample Auto Profile - Gravity Velocity Trigger can be downloaded to your RAPT account and can then be adjusted to suit if required. It illustatres how easy it is to have an automatic profile that suits almost every ale fermentation, and can easily be tweaked to suit lagers.

    For more information about this and other features please watch this video.

    NOTE: It is completely normal for there to be a temperature variance between the built in probe and the Bluetooth enabled RAPT device. This is because the Bluetooth device is measuring the temperature of the fermentation (typically), and the internal probe is measuring the air temperature of the RAPT Temperature Controller. This difference will be greater when the RAPT Temperature Controller is actively heating or cooling.

    The Allowed Sensor Diff. Iin the Settings menu) sets the allowed temperature differential between the desired setpoint and the current temperature of the Fermentation Chamber. Cooling and Heating is disabled temporarily if this differential is exceeded. The default differential setting is 5°C. This value is suitable for typical use.

    This differential can be altered in the Settings menu. If the temperature differential is exceeded, the RAPT Temperature Controller will suspend heating and cooling until the differential is reduced. The legend DIFF OVERRIDE will also be displayed when the display is in Graph Disabled Mode.

    The RAPT Temperature Controller will suspend active cooling or heating and resume as needed – no intervention is required. Once the differential is reduced then heating and cooling will continue as normal.

    The Allowed Sensor Differential can be a powerful tool for temperature control. The default setting of 5°C is perfect for most use cases. However, you may choose to increase the differential to allow for more sustained and thus faster heating or cooling, for example. The Sensor Differential can be reduced as well - meaning that the a, which can be useful if there are large temperature swings during fermentation.llowed temperature swings in the chamber will be reduced.

    Note that in most cases 5°C is appropriate, and too great a differential can causes issues such as freezing.

    NOTE: When using a Bluetooth Bonded RAPT Pill Hydrometer as the temperature probe, it is important to place the RAPT Temperature Controller built in probe in the active fermentation chamber/fridge/freezer.

    Once the Pill has been Bonded to the device

    A note on Allowed Sensor Differential

    Menus

    Menu Guide | RAPT Temperature Controller

    The RAPT Temperature Controller is designed to be largely controlled through the RAPT Portal.

    There are various on board functions which can be accessed directly through the on board menu.

    To use the on board menu, use the Up or Down buttons to navigate. Use the Select button to select or enter a function once highlighted. Use the Cycle/Back button to escape from a Menu option or return to the prvious screen. Selecting Back will not save any changes.

    This option will only be available when the RAPT Temperature Controller is not registered to the RAPT Portal. For a step by step guide to registering your RAPT Temperature Controller please refer to

    To access currently running Profiles, or Profiles that have been uploaded to the device, navigate to and select

    Profiles
    in the menu. From this menu, available Profiles can be started, stopped and paused.

    Active profiles can also be skipped to another step or reverted to a previous step. Please refer to Profiles for a full guide.

    The following options are available in the Settings Menu.

    To change any of the advanced settings enter the Menu by pressing Select . Once in the menu navigate to Settings and press Select

    Up or Down buttons to adjust the set value for the setting. To save your setting hit Select . To return to the menu without saving choose Cycle/Back

    Some options are on/off toggles that can be activated or deactivated from the Settings Menu directly.

    SETTING
    PARAMETER

    Temperature Sensor

    Select built-in probe or select any Bonded Bluetooth RAPT Pill & Hydrometer

    Show Graph

    Toggles display between the graph or a numerical display

    Unit System

    Toggles between metric or imperial data

    Bluetooth needs to first be enabled in the Settings menu (above).

    To Bond a Bluetooth enabled RAPT devices, use the Up or Down buttons to scroll to select the device. Choose Select button to Bond the device, or the Cycle/Back button to cancel.

    Once Bonded, the device will be visible in the Bonded section of the Bluetooth Menu. To Unbond, select the device with the navigation arrows and choose Select buttont to Unbond the device, or the Cycle/Back button to cancel.

    For more information about Bluetooth operation refer to the Bluetooth section.

    NOTE: When using a Bluetooth Bonded RAPT Pill Hydrometer as the temperature probe, it is important to place the RAPT Temperature Controller built in robe in the active fermentation chamber/fridge/freezer.

    The Diagnostics menu contains information about the RAPT Temperature Controller. This includes such information as current firmware version, Wi-Fi network and signal strength, MAC address and IP address of the device.

    The About menu contains information specific to the firmware and software of the RAPT Temperature Controller and associated devices, including but not limited to copyright information, acknowledgment of open source properties used, legal information etc.

    Register Device

    Profiles

    Getting Started

    Settings

    Bluetooth

    Diagnostics

    About

    RAPT Device Boot Loop Troubleshooting & Recovery Mode

    How to fix a RAPT device that is boot looping | Recovery Mode Guide

    If your RAPT device boots up but continually ‘loops’ back to the start up logo, this indicates that the device is stuck in a ‘boot loop’

    This can happen for several reasons including but not limited to a failed firmware download, power interruption during install, poor network strength.

    A Boot Loop can occur on any RAPT device with a screen – including but not limited to RAPT Fermentation Chambers, RAPT Temperature Controllers, Gen 4 RAPT BrewZillas.

    A Boot Loop issue is quite easily rectified.

    Generally, a Boot Loop can be resolved by resetting NVS.

    An NVS reset is performed using the following steps.

    Graph zoom level

    Select the date range displayed on the graph (default 7 days)

    Cooling Hysteresis

    Sets the cooling hysteresis (range 0.0°C-10°C, default 1°C)

    Heating Hysteresis

    Sets the heating hysteresis (range 0.0°C-10°C, default 1°C)

    Compressor Cooldown

    Sets the minimum compressor delay (Range 0-10 minutes, default 5 minutes)

    Mode Switch Delay

    Sets the minimum mode switch delay (Range 0-30 minutes, default 15 minutes)

    Cooler Enabled

    Toggles cooling on or off (when unchecked, the cooling will not operate irrespective of other settings)

    Heater Enabled

    Toggles heating on or off (when unchecked, the heater will not operate irrespective of other settings)

    Bluetooth Enabled

    Toggles Bluetooth functionality on or off

    Allowed Sensor Diff.

    This sets the allowed temperature differential between the built in probe and the current setpoint when using a Bluetooth device for temperature control (range 1°C-50°C, default 5°C). See Bluetooth Operation

    Sensor timeout

    Sets the timeout if a Bluetooth device drops out (reverts to internal probe) (Range 5-1800 seconds, default 900 seconds)

    Sounds Enabled

    Toggles device sounds on or off

    Calibration Point 1

    First Calibration Point (see Calibration)

    Calibration Point 2

    Second Calibration Point (see Calibration)

    Forget Calibration

    Deletes saved calibration settings and restores defaults

    NTC Beta

    Enter the NTC Beta of an external temperature probe. The default is 3950

    NTC Ref. Temperature

    Enter the NTC Ref. Temperature of an external temperature probe. The default is 298.2

    NTC Ref. Resistance

    Enter the NTC Ref. Resistance of an external temperature probe. The default is 100000

    Relay Cycle Time

    Sets the allowed cycle time for PID heating (Range 5-3600 seconds, default 5 seconds)

    PID Heating

    Toggles PID heating on or off (recommended for advanced users only)

    Heat P Coefficient

    Enter desired proportional PID coefficient (Default 0.500)

    Heat I Coefficient

    Enter desired integral PID coefficient (Default 0.0000)

    Heat D Coefficient

    Enter desired derivative PID coefficient (Default 0.0000)

    Forget WiFi Config

    Forgets existing WiFi config - useful if you change WiFI networks

    Disable WiFi

    Disables WiFi (if you wish to not use the RAPT Portal and have only manual control)

    Clear Registration

    Clears RAPT Portal registration (see Troubleshooting)

    Low Temp. Alarm

    This is the temperature below which an alarm will sound (default -10°C)

    High Temp. Alarm

    This is the temperature above which an alarm will sound (default 50°C)

    Check For OTA Update

    Manually check and download any available firmware updates

    You may require assistance, as you need to unplug the device and re-plug it while accessing the control panel.

    STEP 1: : Unplug the RAPT device that is boot-looping.

    STEP 2: Hold down the Up or Down buttons on the RAPT device

    STEP 3: While holding the buttons down, plug the RAPT device back in. Keep the two buttons held down while the unit boots up.

    Note: it is quite helpful to have another person assist with this.

    STEP 4: The device will reboot, and also clear NVS. This will reset the unit (so it will forget the current WiFi config and Registration settings unfortunately) but it will also restore it to the last stable firmware condition.

    STEP 5: Once rebooted, you can go through the initial steps required to connect the device to your WiFi network. (See the appropraite Get Started! guide for step by step instructions if required)

    STEP 6: One connected to WiFi, please navigate to Check for OTA Update in the Settings menu and select this. This will download and install the current firmware.

    Please ensure you have a decent, stable WiFi signal before updating, as dropouts during this can cause 'boot loop' issues as experienced.

    STEP 7: This operation may need to be performed a couple of times to be successful. A successful NVS reset will display a Connect this device to the Internet message after booting up. If this does not appear please perform the reset operation again.

    In the unlikely event that an NVS reset does not fix a boot loop issue, we can perform a full reset into recovery mode. This will reset the device back to factory defaults, and restore it to the last verified firmware.

    Recovery mode operates as a bootloader which gives access to settings independant of firmware. This can be useful in some situations such as experiencing issues with your RAPT device due to a corrupt firmware or a problem with a firmware update.

    Typically the avergae user will not need to enter Recovery Mode.

    STEP 1: Enter Recovery Mode

    Unplug the RAPT device, then plug it back in while holding all 4 main buttons down - Up or Down Select Cycle/Back

    Once it boots up, you will see a screen called Recovery Mode Main Menu

    STEP 2: Select option [0] Rollback last OTA update and reset.

    Use the Up or Down buttons to select the required option [0] then select Cycle/Back to do this.

    If successful, the message Rollback to previous firmware worked will be displayed, and the RAPT device will reboot. You may then need to reconnect the RAPT device to your WiFi network and perform an OTA firmware update, then re-register the device to your RAPT account.

    STEP 3: If unsuccessful, the message Rollback is not possible will be displayed, and the unit will stay in Recovery Mode.

    You will need to manually connect the RAPT device to WiFi and update the firmware manually while in Recovery Mode.

    As there is no on screen keyboard, the easiest way to do this is to setup a HotSpot on your phone with a super simple network name and password – such as all capital 'A's for the name and password.

    Thus create a HotSpot network name of AA and a password of AAAAAAAA.

    Use the Up or Down buttons to select option [1] Connect To Wifi.

    Follow the onscreen instructions to enter the SSID and Password on the controller.

    Otherwise use the navigation keys to enter your home WiFi Network SSID and Password manually

    Once connected to the network, the RAPT device will go back to the main Recovery Mode menu. This time, select option [2] Do OTA Update

    This will update the RAPT device firmware. Once this is down, please unplug the RAPT device then plug it back in after 30 seconds. It will now start up properly.

    If you used a custom mobile phone hotspot to connect you will now need to connect the RAPT device to your home WiFi network. Please refer to the online user manual for step by step instructions. The RAPT device will also need to be re-registered to your RAPT account after this.

    In the unlikely event that resetting NVS and entering Recovery Mode does not fix a boot loop issue, please contact KegLand at beer@kegland.com.au or your local retailer for warranty support.

    Symptoms

    Fixing a Boot Loop by resetting NVS (Non Volatile Storage)

    Recovery Mode

    Fixing a Boot Loop by resetting into Recovery Mode

    Troubleshooting

    Troubleshoot | RAPT Temperature Controller

    Problem
    Solution

    Cannot open Captive Portal

    Check that WiFi is active on your mobile device

    If updating the firmware persistently fails or throws an error, and all troubleshooting steps have failed, then try using your mobile phone as a Hotspot to resolve this.

    Using the phone as a Hotspot will typically solve firmware update issues of this kind

    1: It helps eliminate potential network or modem/router issues which can cause problems that can be hard to isolate and resolve

    2: It can help eliminate signal strength or poor WiFi connection issues as the phone can be positioned right next to the RAPT device when in Hotspot mode.

    To connect to the phone Hotspot and update the firmware there are a few steps to follow

    1. On the phone, turn WiFi OFF. When troubleshooting firmware download or network issues, we do not want to use the same network thus the phone must be disconnected from the WiFi network in order to do this

    2. Enable Personal Hotspot (sometimes just called Hotspot) on your phone. This is typically located under the WiFi or Network menu in the Settings menu of the phone. On IOS this is under Settings/Personal Hotspot. The menu names will vary on Android depending on device

    3. Enable Maximise Compatibility (on IOS) or 2.4gHz Network Only

    (on Android - again, this will have different names depending on device/OS). This will help minimise issues when connecting
  • Once Hotspot is enabled on the device, following the steps in to connect to the phone Hotspot

  • Once connected, navigate to Settings/Check for OTA update on the RAPT Device

  • Select KegLand RAPT XXXX network

    Enter password 'kegland1'

    Cannot see KegLand RAPT XXX in my list of available networks

    Navigate to Settings and Enable WiFI

    Unplug the device for 30 seconds, then plug it back in and refresh the list of networks on your mobile device

    This may already be connected to WiFi. Check the IP (STA) in Diagnostics. If this is populated with an IP address that is not 0.0.0.0 then this is already connected

    "Selected Network is not connected to the Internet" error

    Select the KegLand RAPT XXX network and choose "Forget This Network"

    Device does not connect to my WiFi network

    Check that your network is broadcasting a 2.4gHz signal

    Non alphanumeric characters in the SSID or password can cause issues - change these to simple (letters and numbers only) characters

    Ensure you are selecting the correct network and inputting the correct password for that network

    The network must have a password – the device cannot connect to an unsecured network

    The device may already be connected. Check the IP (STA) in Diagnostics. If this is populated with an IP address that is not 0.0.0.0 then the device is likely already connected

    Reboot the device by unplugging for at least 309 seconds

    Reboot your modem/WiFi router

    Try connecting to a different WiFi network

    Turn off any VPN or anything that can block an outgoing signal on the router

    If the above do not work, see below

    Cannot see a Validation Code

    Connect the device to your WiFi network

    Update the firmware - select Check for OTA update in Settings

    Error when Registering device

    Check that the device firmware is up to date - select Check for OTA update in the DIagnostics screen

    The Validation Code may have timed out. Reboot the device by unplugging it for at least 30 seconds, then plugging it back in. Log out of the RAPT Portal and log back in

    If the above steps do not work, reboot the network that the device is connected to. Once the network has rebooted, reboot the device by unplugging it for at least 30 seconds, then plugging it back in. Log out of the RAPT Portal and log back in. Note: if using a modem and seperate wifi roters, reboot the modem and then the wifi routers in that order.

    A corrupt firmware install can prevent registration. This can happen if a firmware download is interrputed, for example. If the above steps do not allow registration, please refer to to rollback firmware to a good version, then update to the current version

    Determine whether your device is connected to Wi-Fi

    To check this navigate to Diagnostics and check that it shows your network’s IP address next to IP (STA) - in the form 192.168.XX.XXX or similar. You can also check the WiFi AP (Access Point ) the device is connected to and the current WiFi signal strength

    Determine whether your device is registered to the RAPT Portal

    If the message "Register your device by pressing the select button to enter the main menu, then selecting the "Register Device" item in the main menu" is displayed, this is not registered. Please follow the steps outlined in Register Device

    Cannot update firmware | 5379 Error

    This is a network issue. The OTA Firmware Update could not be validated or was incomplete. Ensure your device is as close as possible to the router. Check signal strength in Diagnostics

    Ensure you have a strong 2.4gHz WiFi signal (not just 5gHZ). Check your signal strength against

    Make sure there are no VPNs in use, or filters or other potential issues set up in the router that can block an outgoing signal

    If issues persist, reboot the device and also the modem

    If the above do not work, see below

    Cannot update firmware | 28674 Error

    This is a network issue. The OTA Firmware Update could not be validated or was incomplete. Ensure your device is as close as possible to the router. Check signal strength in Diagnostics

    Error 28674 is an error opening an HTTP connection. Check your modem or router settings. A VPN, Firewall or other setting may be blocking outgoing connections - this is a common reason for this error

    Ensure you have a strong 2.4gHz WiFi signal (not just 5gHZ). Check your signal strength against

    If issues persist, reboot the device and also the modem

    If the above do not work, see below

    SIgnal Strength

    Using Phone as Hotspot

    SIgnal Strength Table
    Getting Started
    Using Phone as Hotspot
    RAPT Device Boot Loop Troubleshooting & Recovery Mode
    this table
    Using Phone as Hotspot
    this table
    Using Phone as Hotspot
    Bond RAPT Pill with RAPT Fermentation Chamber or Temperature Controller