> For the complete documentation index, see [llms.txt](https://docs.rapt.io/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.rapt.io/equipment/rapt-pill-hydrometer-or-user-guide/bluetooth-operation.md).

# Bluetooth Operation

RAPT Pill Hydrometer & Thermometer - Bluetooth Operation Guide

### Bluetooth Setup and Bonding

The RAPT Pill can send telemetry via WiFI or Bluetooth. For general use WiFi is the default option.&#x20;

Bluetooth is the best option if the RAPT Pill Hydrometer is used with a Bluetooth capable RAPT device such as a RAPT Fermentation Chamber, a RAPT Temperature Controller, a RAPT Glycol Chiller or another RAPT relay device.

### Benefits of Bluetooth Operation

Once a RAPT Pill Hydrometer is set to Bluetooth Telemetry and Bonded with a compatible RAPT device (such as a RAPT Fermentation Chamber or a RAPT Temperature Controller) the Pill Hydrometer can be used as a temperature probe for that RAPT device.

This is fantastically powerful.

As well as transmitting temperature information, the RAPT Pill will also send both Gravity and Gravity Velocity to the Bonded RAPT device.

This allows the use of powerful and complex **Fermentation Automations**

For example, you can select to have the temperature maintained until a set gravity is reached. You may prefer to ramp the fermentation temperature when the Gravity Velocity slows to a certain level. This functionality is unlocked via Bluetooth!

Setting the RAPT Pill Hydrometer to Bluetooth mode will also have a positive effect on battery life as far less enegery is used to send telemtry via Bluetooth compared to Wifi, so the battery will last significantly longer.

{% embed url="<https://youtu.be/oVNjjFeZWxk>" %}

### Enable Bluetooth Telemetry

{% columns %}
{% column %}
To enable Bluetooth on the RAPT Pill, you must first connect to the Pill in the RAPT Brew App.

Once **Connected**, open **Setup** and select **Telemetry via Bluetooth.** Select **Apply** to save the changes

The default telemetry interval for WiFi is 60 minutes.

The default telemetry interval for Bluetooth is 5 minutes

It is not recommended to set shorter telemetry intervals. Shorter intervals will impact battery life.&#x20;
{% endcolumn %}

{% column %}

<figure><img src="https://570278281-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FUqN4sW0x2s4yh6iiT8NN%2Fuploads%2FeBdymvGU7nJvuIj6bQml%2Fimage.png?alt=media&amp;token=0635c2da-dc3a-48e5-a5bc-88cbd0e5e080" alt=""><figcaption></figcaption></figure>
{% endcolumn %}
{% endcolumns %}

{% hint style="info" %}
**Recommended telemetry intervals are 60 minutes for Wifi and 5 minutes for Bluetooth – this provides the best combination of accurate reporting and battery life.**
{% endhint %}

Once Bluetooth has been enabled in the Pill Captive Portal, the Pill must be Bonded with a RAPT Bluetooth device such as a RAPT Fermentation Chamber, a RAPT Temperature Controller.

**Note: Bluetooth telemetry control requires a compatible RAPT device such as a Fermentation Chamber or Temperature Controller.**&#x20;

When a Pill has been bonded with a compatible RAPT device the RAPT device can then be set to use the Pill as the Temperature Sensor. Doing this allows temperature control using real time telemetry from the bonded Pill. This will also display up to date temperature and gravity data on the RAPT device.

For further information about Temperature Sensor control using a Bluetooth Bonded Pill refer to the Bluetooth section of the relevant device User Guide - [**RAPT Fermentation Chamber**](https://docs.rapt.io/equipment/rapt-fermentation-chamber-or-user-guide/bluetooth.md) **or** [**RAPT Temperature Controller**](https://docs.rapt.io/equipment/rapt-temperature-controller/bluetooth)