# Calibration

RAPT Can & Bottle Filler | Calibration Guide

## <img src="https://570278281-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FUqN4sW0x2s4yh6iiT8NN%2Fuploads%2FeG87SogNhknwVCovbp2P%2Fwarning-sign%20(1).png?alt=media&amp;token=0565d3fe-6bda-40ea-954a-ab3af0c0de47" alt="" data-size="line"> Mandatory Firmware Check

{% hint style="info" %}
Please Note: The calibration process was significantly updated on 30/01/2025. To ensure your device operates correctly and follows the steps in this manual, you must be running this firmware version or newer.
{% endhint %}

{% stepper %}
{% step %}

### Prepare the Machine

**Mark the Purge Tube:** Locate the stainless steel purge dip tube (on the right side of the unit). Measure 100mm up from the bottom of the tube and mark this clearly with a wipeable marker.

**Connect Gas:** Attach your gas line to the red carbonation cap. This is required to clear the line during the calibration process.
{% endstep %}

{% step %}

### Enter Calibration Mode

To enter the calibration mode: **Select** <img src="https://docs.rapt.io/~gitbook/image?url=https%3A%2F%2F570278281-files.gitbook.io%2F%7E%2Ffiles%2Fv0%2Fb%2Fgitbook-x-prod.appspot.com%2Fo%2Fspaces%252FUqN4sW0x2s4yh6iiT8NN%252Fuploads%252FJVin8Ct47ODMRC9a2qab%252FENTER%2520RAPT.png%3Falt%3Dmedia%26token%3D077fda61-812a-4aaa-8693-2e8d66c23e2e&#x26;width=40&#x26;dpr=4&#x26;quality=100&#x26;sign=731735a3&#x26;sv=1" alt="" data-size="line"> then navigate through the menu to **Calibrate** then press **Fill**.
{% endstep %}

{% step %}

### Set the 1st Calibration Point (Ambient/Empty)

**Clear the Line:** Remove the purge tube from container or liquid. Press **Select** <img src="https://docs.rapt.io/~gitbook/image?url=https%3A%2F%2F570278281-files.gitbook.io%2F%7E%2Ffiles%2Fv0%2Fb%2Fgitbook-x-prod.appspot.com%2Fo%2Fspaces%252FUqN4sW0x2s4yh6iiT8NN%252Fuploads%252FJVin8Ct47ODMRC9a2qab%252FENTER%2520RAPT.png%3Falt%3Dmedia%26token%3D077fda61-812a-4aaa-8693-2e8d66c23e2e&#x26;width=40&#x26;dpr=4&#x26;quality=100&#x26;sign=731735a3&#x26;sv=1" alt="" data-size="line">.&#x20;

**Capture Reading:** Press **Select** <img src="https://docs.rapt.io/~gitbook/image?url=https%3A%2F%2F570278281-files.gitbook.io%2F%7E%2Ffiles%2Fv0%2Fb%2Fgitbook-x-prod.appspot.com%2Fo%2Fspaces%252FUqN4sW0x2s4yh6iiT8NN%252Fuploads%252FJVin8Ct47ODMRC9a2qab%252FENTER%2520RAPT.png%3Falt%3Dmedia%26token%3D077fda61-812a-4aaa-8693-2e8d66c23e2e&#x26;width=40&#x26;dpr=4&#x26;quality=100&#x26;sign=731735a3&#x26;sv=1" alt="" data-size="line">. The unit will purge the line and display `Purging > Waiting for Pressure to Stabilize`. This sets the baseline "zero" value for ambient pressure.
{% endstep %}

{% step %}

### Set the 2nd Calibration Point (Reference Height)

**Prepare Reference Water:** Place a container (a glass is ideal) under the fill & purge tubes. Fill it with water until the water level exactly hits the 100mm mark you made in Step 1.

**Check Value:** Ensure the measurement value on the screen matches the height of your water (e.g., 100mm). If you used a different height, update the value on the screen now.

**Capture Reading:** Wait for the pressure sensor value to stabilise (fluctuating by only a few points). **Select** <img src="https://docs.rapt.io/~gitbook/image?url=https%3A%2F%2F570278281-files.gitbook.io%2F%7E%2Ffiles%2Fv0%2Fb%2Fgitbook-x-prod.appspot.com%2Fo%2Fspaces%252FUqN4sW0x2s4yh6iiT8NN%252Fuploads%252FJVin8Ct47ODMRC9a2qab%252FENTER%2520RAPT.png%3Falt%3Dmedia%26token%3D077fda61-812a-4aaa-8693-2e8d66c23e2e&#x26;width=40&#x26;dpr=4&#x26;quality=100&#x26;sign=731735a3&#x26;sv=1" alt="" data-size="line">. The unit now knows the pressure-to-depth ratio.
{% endstep %}

{% step %}

### Run a Test Fill With Water

**Set Your Target:** Place your actual can or bottle in the filling position. Decide where you want the liquid to stop and mark that spot on the purge tube.

**Measure & Program:** Measure from the bottom of the tube up to this new mark. Enter this value (in mm) into your Fill Preset.

**Test:** Connect your water source to the yellow carbonation cap (max 15psi). Select your preset, place your container, and press Run.
{% endstep %}
{% endstepper %}

<table data-view="cards"><thead><tr><th data-hidden data-card-cover data-type="image">Cover image</th><th data-hidden data-card-target data-type="content-ref"></th></tr></thead><tbody><tr><td><a href="https://570278281-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FUqN4sW0x2s4yh6iiT8NN%2Fuploads%2F7SL2Os5UnYM2bvHf8Som%2FCan%20%26%20Bottle%20Filler%20Calibration%20%20-%20Play.png?alt=media&amp;token=4f871d25-6f47-4c10-909d-c9833f13b3f0">Can &amp; Bottle Filler Calibration  - Play.png</a></td><td><a href="https://youtu.be/BZ8N-igzbTM?si=pAt4P460Uk-ikJFR&#x26;t=305">https://youtu.be/BZ8N-igzbTM?si=pAt4P460Uk-ikJFR&#x26;t=305</a></td></tr></tbody></table>