Replacement Screen Board/Controller - Toggle Selection
If you replace either the KL20305 BrewZilla Gen 4 - RAPT Screen Controller Case with Wire and LCD Screen Board or the KL30106 BrewZilla Gen 4 - LCD Screen Board then it is important to select the correct model of Gen 4 BrewZIlla before installing the Controller or Screen Board.
This is a manual toggle mswitch on the board that selects the power of the corresponding Gen 4 BrewZilla unit.
This is easy to do and will only take a moment.
Test the Screen Controller
To ensure that this has been selected correctly, once the housing has been reassembled, plug the controller into the BrewZill and plug the BrewZilla into an outlet to turn it on. Once it has booted up, check that the Play/Pause button is off so that the elementsa are not energised. Use the Cycle/Back button to navigate to power settings. If necessary, change the power to 100%. The displayed wattage should now reflect the wattage of the BrewZilla based on boiler size
See below for correct power outputs
Location of Toggle Switch on Screen Board

Close View of Toggle Switch

Correct Power Outputs
35L Gen 4 BrewZilla: 100% = 2400W
65L Gen 4 BrewZilla: 100% = 3500W
100L Gen 4 BrewZilla: 100% = 6600W