# Assembly

### PolyPhoenix Air Still Pro Included Components

{% columns %}
{% column %}

1. PolyPhoenix Air Still Head
2. PolyPhoenix Air Still Boiler
3. Indicator Light
4. Reset Button
5. Main Column
6. Male IEC Cable
7. Foreshots Collection Jar
8. Distillation Nipple
9. Distillation Outlet
10. Distillation Nipple Inserts
11. Controller
12. Basket/Column Cap
    {% endcolumn %}

{% column %}

<figure><img src="/files/GcoRaWp2O0RRrk8HO0cx" alt="" width="563"><figcaption></figcaption></figure>
{% endcolumn %}
{% endcolumns %}

#### Also included:

KL32704 [Large Spiral Prismatic Packing 7mm (OD) x 3.6mm](https://kegland.com.au/products/spiral-prismatic-packing-spp-500g-od0-4mm-x-h3-6mm) (to fill the column for Reflux Mode)

Gin Basket installed (under 12: Basket/Column Cap) - this does not need to be removed if not used during a run

Standard IEC Cable

#### Included Outlet Nipples

**1.2mm Nipple Insert** - suitable for Stripping Runs and Pot Still operation\
**0.5mm Nipple Insert** - High Purity (with SPP installed) and faster run time for reflux mode\
**0.3mm Nipple Insert** - Highest Purity (with SPP installed), slowest run time for reflux mode

### Assembly

After unboxing the PolyPhoenix Air Still Pro Head and the PolyPhoenix Air Still Pro Boiler, check that you have all listed components.

Fit the Air Still Head onto the Boiler.

{% columns %}
{% column %}
Fit the Air Still Head onto the Boiler.

**NOTE**: The boiler clamps are not concentric. This is by design to ensure that the Air Still Head is correctly oriented. When attached, the Reset button on the boiler will be to the left of the column, and the power outlet will be on the right as shown.

**NOTE**: Do not plug the boiler in until assembly is complete
{% endcolumn %}

{% column %}

<figure><img src="/files/DXFRzuGtJms7rAprLyQP" alt=""><figcaption></figcaption></figure>
{% endcolumn %}
{% endcolumns %}

{% columns %}
{% column %}
Next, check that the Outlet Nipple is installed. For initial cleaning, we recommend swapping this for the 1.2mm Outlet. Spare Outlets are stored in the top of the Distillation Outlet (1). To remove the installed Outlet, unscrew it anticlockwise. To install a different Outlet, screw it in clockwise until snug. Finger tight is sufficient to seal

{% endcolumn %}

{% column %}

<figure><img src="/files/AOdwAOrDdSJQaWtq7l9W" alt=""><figcaption></figcaption></figure>
{% endcolumn %}
{% endcolumns %}

{% columns %}
{% column %}
Underneath the column, check that the stainless packing plug is secure. Remove the Column Cap (2) and Gin Basket (3)

Carefully open the plastic bag filled with  7mm (OD) x 3.6mm. Carefully pour the SPP into the column. Replace the Gin Basket and Column Cap.

Ensure that the foreshots collection jar is installed snugly (4)
{% endcolumn %}

{% column %}

<figure><img src="/files/9Bc7eoHyK7VOFhs6QToE" alt=""><figcaption></figcaption></figure>
{% endcolumn %}
{% endcolumns %}

{% columns %}
{% column %}
Ensure that the foreshots collection jar is installed snugly (4)

To complete the assembly, the Air Still Head needs to be plugged into the Air Still Boiler. Then plug the included IEC cable into the IEC socket on the Air Still Column and connect the IEC cable to a standard 10amp power outlet.
{% endcolumn %}

{% column %}

<figure><img src="/files/D7sh4Clr6NSl5LMFLuZC" alt=""><figcaption></figcaption></figure>
{% endcolumn %}
{% endcolumns %}

### Relief Valve

There is a Relief Valve under the Outlet Head next to the Foreshots Collection Jar. This is an important safety feature and should never be blocked.

The relief valve will only operate if excess pressure develops in the Still Head. In normal operation, this is extremely unlikely. You may notice a couple of drips from the relief valve at the very start of a run. This is normal and nothing to worry about. If the relief valve continues to drip during the run the PolyPhoenix Air Still Pro will shut down automatically once the Ethanol Sensor threshold is triggered.&#x20;

If using an external boiler with the PolyPhoenix Air Still Pro Head, shut the boiler down or drop the power to the boiler if there are drips coming from the Relief Valve.

{% embed url="<https://www.youtube.com/embed/bz0mp8Qw7Kg>" %}


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.rapt.io/equipment/polyphoenix-air-still-pro-table-top-distillation-kit-user-guide/assembly.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.